27
Step 3: Tight the Terminals
Use a 3mm hexagonal torque wrench to tight the hexagonal screws on A, B, C and PE Terminals .The
nominal torque to tight these terminals is 4.0 ~ 4.5Nm. If the tight torque reaches higher than
8.5Nm, the terminal will be broken.
Step 4: Cable Fixing
Use a hose clamp to fix the cable on the cable support. Make sure that the cable shield has a large-
area contact against the cable support, so that they can together be grounded through drive
housing.