background image

 

 

3.2

 

PRESET

 

OTHER

 

SPECIFICATIONS

 

Press  “

M

”  to  enter  the  user  interface,  which  allows  you  to  select  and  adjust  options  like  VIEW 

MODE,  PROBE  SETUP,  MINIMUM  ALARM,  MAXIMUM  ALARM,  NORMAL  THICKNESS,  MINIMUM  of 
B‐SCAN,  MAXIMUM  of  B‐SCAN,  RECTIFICATION,  RECTIFICATION  WAVEFORM,  RESOLUTION, 
LANGUAGE, UPDATE RATES, UNITS, AND DEFAULT SETUP. See the following figure:     

 

 

 

 

 

 

 

 

 

 

 

3.2

 

Menu

 

Selections

 

VIEW

 

MODE:

 normal mode, difference mode and limit scanning mode.   

PROBE

 

SETUP:

 PT‐10/PT‐08(normal probe), PT‐06(small probe), PT‐04(mini probe), GT‐12(high‐temperature 

probe), and ZT‐12 (cast iron probe). 

MINIMUM

 

ALARM

:  set  the  minimum  thickness  alarm  value.  The  result  will  be  displayed  in  red  if  the  actual 

thickness is less than the minimum value preset. 

MAXIMUM

 

ALARM

:  set  the  maximum  thickness  alarm  value.  The  result  will  be  displayed  in  red  if  the  actual 

thickness is more than the maximum value preset. 

NORMAL

 

THICKNESS:

  set  the  normal  thickness.  The  real  concrete  application  will  be  introduced  in  the 

DIFFERENCE

 

MODE

MINIMUM

 

of

 

B

SCAN

: set minimum thickness for B‐scan 

MAXIMUM

 

of

 

B

SCAN

: set maximum thickness for B‐scan 

RECTIFICATION

 

MODE:

  RF,  full  wave,  half  ‐,  half  +.  RF  describes  the  complete  echo  waveform;  full  wave 

indicates the half + echo and the overturned half ‐ echo; half – means putting off the half + echo and turn the half 

– over to +; half + means putting off the half – echo and only left the half + echo.   

RECTIFICATION

 

WAVEFORM:

 outline mode and fill mode. 

RESOLUTION:

 

Selectable Resolution: 0.001”, 0.01” or .01mm 

LANGUAGE:

 the interface language: Chinese or English

Summary of Contents for UTG-4000

Page 1: ...l No UTG 4000 www phase2plus com 283 Veterans Blvd Carlstadt NJ 07072 201 933 6300 www phase2plus com 21 Industrial Ave Upper Saddle River NJ 07458 P 201 962 7373 F 201 962 8353 E mail info phase2plus...

Page 2: ...D FUCTIONS 5 3 MEASURING THE THICKNESS 6 3 1 PRESET THE MATERIAL S VELOCITY 6 3 2 PRESET OTHER SPECIFICATIONS 7 3 3 CALIBRATION 8 3 4 DISPLAY MODES 9 3 5 ADJUSTING THE SPECIFICATIONS IN A SCAN MODE 11...

Page 3: ...wn thickness or sound velocity 1 1 CONSTRUCTION OF THE GAGE 1 2 STANDARD CONFIGURATION Qty Thickness Gauge 1 5MHz PROBE 1 AA Batteries 2 2oz Couplant Gel 1 Rugged Carry case 1 Operation Manual 1 1 3 O...

Page 4: ...Error 0 001 up to 0 984 0 007 up to 3 03 0 019 4 and above Display Modes Digital Thickness Readout A scan or B scan Min Max Capture Diff Value Reduction V Path Correction Automatic Update Rate Selecta...

Page 5: ...mode getting the difference between the actual value and the normal value as well as the percentage 8 Inch Metric Conversion 9 Extra large memory up to 100 000 values 1000 waveforms 10 Selectable Reso...

Page 6: ...may be different from the actual material velocity intended to be measured Calibration to a known thickness Note This procedure requires a sample piece of the specific material to be measured the exa...

Page 7: ...ctual thickness is less than the minimum value preset MAXIMUM ALARM set the maximum thickness alarm value The result will be displayed in red if the actual thickness is more than the maximum value pre...

Page 8: ...TION STEP ILLUSTRATION 1 Adjust the sound velocity to 5900m s according to the method in chapter 3 1 2 After turning on the gage press to enter the calibration interface The screen shows PUT PROBE ON...

Page 9: ...in GREEN When the values exceed the upper or lower limit setting then the values will be shown in RED THICKNESS VALUE MODE This interface mainly shows the velocity of material the present thickness va...

Page 10: ...ITS VALUE SCANNING MODE this mode allows the customer to test the thickness of material continuously and to show the upper lower limits after the tests It shows the minimum and maximum values during t...

Page 11: ...robe and the object are not completely coupled the letters in the various interfaces are shown in GREEN when properly coupled they are displayed in WHITE color and when the either the upper or lower l...

Page 12: ...this will only show when the GATE specification is highlighted The first intersection point between the waveform and gate is shown with a RED arrow which will help you determine if this thickness valu...

Page 13: ...n be realized by adjusting the gate setting above the defect echoes 3 9 REAL CASE 2 3 If there are some surface faults in the testing object and the gate locks the defect echoes the measuring result w...

Page 14: ...ty 10 The minimum thickness value on the B scan image 11 Parameter display area 12 Gain value 3 72 Introduction to B scan The UTG 4000 has a time base B scan function By moving the probe across the su...

Page 15: ...icates the length of echo blanking the waveform above this is considered invalid See fig 3 16 below 1 Identification of dual echo mode 2 Blue arrow indicates secondary echo 3 E blanking 4 Blue line th...

Page 16: ...ferred to your PC via USB output and saved as an EXCEL or TXT file 4 1 THICKNESS VALUE AND WAVEFORM STORAGE 1 Storage file number 2 Line mark 3 Row mark 4 Data in memory 5 Return to main menu 6 Save c...

Page 17: ...l attention to polarity Attention when not using the gauge for extended periods of time please remove batteries to prevent any leakage or corrosion 5 2Maintenance 1 Always keep your gauge probe cable...

Page 18: ...t or near the temperature of the material to be measured This will allow the gauge to correctly calculate the velocity of sound through the hot material When performing measurements on hot surfaces it...

Page 19: ...d in ultrasonic thickness measurement does not travel through air efficiently A wide variety of couplant materials may be used in ultrasonic gauging Propylene glycol is suitable for most applications...

Page 20: ...n 0 230 5900 Iron cast 0 180 4600 Lead 0 085 2200 Magnesium 0 230 5800 Mercury 0 057 1400 Molybdenum 0 250 6300 Monel 0 210 5400 Neoprene 0 063 1600 Nickel 0 220 5600 Nylon 6 6 0 100 2600 Oil SAE 30 0...

Page 21: ...t Beijing 100192 China Tel 86 10 59792409 Fax 86 10 59814851 General E mail info phase2china com cn MEXICO Phase II de Mexico Calle A No 4 Promer Piso Col San Marcos Azcapotzalco C P 02020 Mexico Tel...