Phantos LED PAR CAN User Manual Download Page 8

 

to bright

 

 

CH28

 

Ex4-Blue

 

0-255

 

External 4, Blue dimming, dark to 

bright

 

Part 4, Troubleshooting 

4.1 Troubleshooting list for some common electrical 
problems may happen during use: 

Phenomenon 

Solution 

*  The  fixture  does  not 
work 
* No light out 

*  Check  main  power  fuse  &  power  cable 
connection 
* Measure main voltage on the main connector 

* No display 

* Check connection of display PCB 
* Replace a new display 

*  No  responding  to 
DMX 
    controller 

*  Check  working  mode  setting  on  display  is  DMX 
mode or not 
* Check whether the unit be set as SLAVE 
* Check DMX address settings 
* Check DMX cable and it’s connection 
* Try to use another DMX console 

* Signal error while use 
DMX 

* Check whether DMX cables be connected well or 
not 
*  Check  whether  the  DMX  cable  has  to  be 
terminated  with  a  terminator  to  reduce  signal 
errors.  If  not,  please  Solder  a  120-ohm  1/4W 
resistor  between  pin  2(DMX-)  and  pin  3(DMX+) 
into  a  3-pin  XLR-plug  and  plug  it  in  the 
DMX-output of the last fixture 

 

4.2 Checking steps about why LED lamp not light 

(Example: Red led lamp not light) 

Step 1: Disassemble lighting fixture and use multi-meter to measure input 
voltage between R+/ R- on main PCB. There should have DC48V.       

  If there no 48V voltage, please check the electro circuit and parts such as 

CQ12, R39, R37, Q3 and etc. 

  If there have 48V voltage, please go to step 2. 

Step 2: Check voltage between R+ and R- on LED lamp PCB and it should be

 

48V. 

  If there has voltage, but LED lamp not work, the reason may be LED lamp 

Summary of Contents for LED PAR CAN

Page 1: ...D USER MANUAL Thank you very much for choosing our product For safety purpose please read this manual carefully before your operation This manual included installation and using information Please install and operate it according to this manual ...

Page 2: ...aster Slave Sound active Beam angle 25 º Net Weight 4 5Kg 1 3 Safety Warning IMPORTANT ALWAYS READ THE USER MANUAL BEFORE OPERATION PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AREA This product must be installed by a qualified professional Always operate the equipment as described in the user manual A minimum distance of 0 5m must be mai...

Page 3: ...iveness is impaired The lamp LED shall be changed if it has become damaged or thermally deformed PART 2 INSTALLATION 2 1 Mounting 2 1 1 Hanging The product can be mounted in a hanging position using the supporting bracket The bracket should be secured to the mounting truss or structure using a standard mounting clamp Please note that when hanging the unit a safety cable should also be used 2 1 2 U...

Page 4: ...Display Panel Operation 3 1 Display panel menu instruction MENU menu selection or return to previous menu UP press UP through the menu list to increase change the value of the current function DOWN press DOWN through the menu list to decrease change the value of the current function ENTER confirm quit out current function setting 3 2 Display panel operation instruction ...

Page 5: ...ht CH3 CH3 Ex Dimmer 0 255 External Dimmer Dark to Bright CH4 CH4 Strobe 0 19 No function 20 199 Normal strobe 200 249 Random strobe 250 255 No function CH5 CH5 In Auto 0 31 No funciton 32 63 Auto 1 speed from slow to fast 64 95 Auto 2 speed from slow to fast 96 127 Auto 3 speed from slow to fast 128 159 Auto 4 speed from slow to fast 160 191 Auto 5 speed from slow to fast ...

Page 6: ...255 Inner Red Dimming Dark to Bright CH8 CH8 In Green 0 255 Inner Green Dimming Dark to Bright CH9 CH9 In Blue 0 255 Inner Blue Dimming Dark to Bright CH10 CH10 In White 0 255 Inner Red Dimming Dark to Bright CH11 CH11 In Amber 0 255 Inner Red Dimming Dark to Bright CH12 CH12 In UV 0 255 Inner Red Dimming Dark to Bright CH13 CH13 Ex1 macro color 0 9 No Function 10 29 R up G 0 B 0 30 49 R 100 G up ...

Page 7: ...x1 Blue 0 255 External 1 Blue dimming dark to bright CH20 Ex2 Red 0 255 External 2 Red dimming dark to bright CH21 Ex2 Green 0 255 External 2 Green dimming dark to bright CH22 Ex2 Blue 0 255 External 2 Blue dimming dark to bright CH23 Ex3 Red 0 255 External 3 Red dimming dark to bright CH24 Ex3 Green 0 255 External 3 Green dimming dark to bright CH25 Ex3 Blue 0 255 External 3 Blue dimming dark to ...

Page 8: ...Signal error while use DMX Check whether DMX cables be connected well or not Check whether the DMX cable has to be terminated with a terminator to reduce signal errors If not please Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 2 Checking steps about why LED lamp not light Example Red led lamp not light Step...

Page 9: ...older to re weld those not be welded led lamp Part 5 Maintenance The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry t...