 Sample number alarm:

 

  Lack of Sample indicator will turn on if the total weight of sample is below   

the limit value, by adding the sample piece with counting until the indicator   
is turned off. Then set the new numbers of sample through numeric key then 
press 

[ SAMPLE/UNIT ]

 key. 

  FREE SAMPLE FUNCTION 

is  the same as the above; scale will 

automatically adjust and  calculate new average unit weight if operator add 
samples in slowly with the numbers. 

  FREE SAMPLE FUNCTION

  will not work if the displayed numbers 

exceed 1,000,000 pieces. 

  b.

 Unit weight alarm:

 

  Lack of Piece Weight indicator will turn on if the averaged unit weight or set 

unit weight is not enough for accurate counting operation. Operator may use 
scale even this indicator turn on, but counting error might occur. 

  c. 

Alarming by press [QTY/SET]:

 

  THE SCALE has useful check function to inform operator that the total piece 

counts quantity has reached the lower limit and the upper limit desired. This 
function is designed for packing purpose. For example,  if the operator wish 
to count 1,000 pieces for  every package, he can set  the lower limit and  the 
upper limit as 1,000 pieces as following: (1)press

[QTY/SET]

 enter quantity 

alarm menu. (2) Setting quantity alarm: repeat step(1), enter quantity alarm 
menu, press 

[ZERO]

 key to selected, selected “CH=on”, this means quantity 

alarm is turn on. If selected “CH=off”, this means quantity alarm is turn off. 
(3) Setting lower limited and upper limit: repeat step (1), enter quantity 
alarm menu, presses 

[TARE]

  key  to selected.  when the display will show 

“L=0000”(L for flash), press digital key, input “990” then press

 [TARE]

 key 

again, input lower limit is complete. The display will show “H=0000”(H for 
flash), press digital key, input “1010” then press

  [TARE] 

key again, input 

upper limit is complete. (4) exit the quantity alarm menu: press

 [QTY/SET]

 

key to exit the quantity alarm menu. 

. Function setting. 

1.

 

Turn off the scale. 

2.

 

press and keep 

[UNIT WEIGHT]

  key then turn on the scale, the display 

will show-----and then b=ON/OFF on the first line, A-XX on the second 

line   

and L=ON/OFF on the third line.  Press 

[QTY/SET]

  to select activate or 

inactivate the function of the beep. Press 

[TARE]

 to select auto off time. Press 

[ZERO]

 key to select activate or inactivate the function of the backlight.. 

3.

 

UNIT WEIGHT function: when there is no weights on the platform, press   

[SAMPLE/UNIT]

 key to select the unit(kg or lb). When there is something on 

the platform, press

 [UNIT WEIGHT

] key to sample. 

unit weight memory   

1.

 

Turn on the scale 

2.

 

Press 0 to 9 to input the unit weight you want to save. 

3.

 

Press 

[STORE] 

to confirm the unit weight and then the display will show 

“c   xxx” . 

4.

 

Press M1 to M9 within 2 seconds, the third line of the display will show “ 

- - -

”. 

Unit weight transfer 

1.

 

Press 

[CE]

 to clear the memory, the second line of the display will show 0. 

2.

 

Press M1 to M9 to transfer the unit weight from memory. 

 

Total weight clear 

1.

 

Press [

TOTAL]

 to show total pieces on the third line of the display. 

2.

 

Press [

MC]

 to show the unit which will be cleared. 

3.  Press 

[CE]

 to confirm clear. 

 
 
 
 
 
 
 
 
 
 
 
 