7.3 LCD 

explanation

 

 
7.3.1 The controller has the three -state normal mode: 
 

Operating 

State 

Information Display 

Description 

Checking 

Check the system parameters , and 

compliance ; 

Fault Mode 

Charge cut down 

Normal state 

charging 

 
7.3.2 Information of LCD in different mode 
 

MPPT 

Information of LCD in different mode

 

              Model 1 
Display 

Boot Mode 

mode\website 

BAT checking 

PV volt checking 

In volsen checking 

Out volsen checking     

Remarks

Shown above automatically next page , according to system conditions, and 

then enter the normal operating mode or failure mode ; 

              Model 2 
Display 

Normal Mode 

Display Model   

Firmware Ver 

Machine ID 

BAT Type 

Chg Cur 

BAT volt 

Opt Power 

PV volt 

In Temp   

10 

Buck 1 Temp 

11 

CC Mode charging   

Summary of Contents for HT-MPPT-192V 50A

Page 1: ...HT MPPT Solar Charge Controller 48V 40A 50A 60A Series User s Manual...

Page 2: ...ety Instructions 4 3 Unpacking 6 4 Assembly 6 5 MPPT controller Connection 7 6 Commissioning 9 7 Meaning of LED and LCD function 10 8 Technical Parameter 13 9 Maintenance and Cleaning 14 10 Storage an...

Page 3: ...components must be stored in the immediate vicinity of the charge controller and must be accessible at all times 1 4 Symbols Used The following types of safety messages and general information appear...

Page 4: ...harge controller can become hot during operation Avoid contact during operation And never put any goods onto the equipment under load Warning Due to high input working voltage please be cautious other...

Page 5: ...nd cautionary markings on the solar charge controller and all corresponding sections of this guide Please use components and parts recommended or sold by I Panda New Energy Otherwise may result in a r...

Page 6: ...re 4 Assembly 4 1 Operator technical personnel 4 2 Selecting the Mounting Location 4 2 1 Dimensions L W H 280mm 180mm 90mm 4 2 2 Net Weight Weight 2 8kg 4 2 3 Ambient Conditions Danger Danger to life...

Page 7: ...sipation Direction Safety clearance Sides 20cm Top 30cm Bottom 20cm 5 MPPT controller Connection 5 1 Safety 5 2 Connections of the PV power system Danger Danger to life due to high voltage in the sola...

Page 8: ...bout 1 2 So we suggest the solar charge controller install near PV module in order to save wire and reduce DC loss DC Output Solar charge controller is designed for battery charging Table 4 Cable and...

Page 9: ...Fasten the lid to the enclosure using eight screws 3 Connect the cables leading from the solar charge controller to the battery 4 Switch on the circuit breaker and the disconnection unit 5 Then turn o...

Page 10: ...Power light green FUNCTION KEY function key LED information Condition Alarm Red Power Blue Standby Green Power on off off on Charge off on on Fault on off on Bat Chose Type off off off In voltage cons...

Page 11: ...different mode MPPT Information of LCD in different mode Model 1 Display Boot Mode 1 mode website 2 BAT checking 3 PV volt checking 4 In volsen checking 5 Out volsen checking Remarks Shown above autom...

Page 12: ...ow solar irradiation In Relay Fault Input relay interrupted Out Volt Low battery voltage is lower than 9 V Out Volt High short circuit overload or over current at battery or PV array also before first...

Page 13: ...ess the key to choose the type of the battery which you need When you press the function key once LCD will display one type of battery Step 3 After choosing the matched battery you need press the func...

Page 14: ...w thermal fuses included in the scope of delivery 4 Close the solar charge controller as described in section Closing the solar charge controller 9 2 Cleaning the Cooling Fin Recommend PV open circuit...

Page 15: ...essing When the controller abnormal please check the following question and contact the customer service representative 11 1 1 Controller failure mode Please check the fault tips in the failure mode a...