The Phaesun Limited Warranty for PV Modules is contingent upon modules 
being mounted in accordance with the requirements described in this section.

5.0 Module Mounting

Phaesun modules should be mounted in locations that meet the following 
requirements:

Care should be taken to provide adequate ventilation 
behind the modules, especially in hot environments.

When mounting modules in snow prone or high wind 
environments, special care should be taken to mount 
the modules in a manner that provides sufficient de-
sign strength while meeting local code requirements.

Excluded Operating Environments:

No Phaesun module should be mounted at a site whe-
re it may be subject to direct contact with salt water.

5.1 Site Considerations

Maximum Operating Temperature

+90 °C, +194 °F

Minimum Operating Temperature

–40 °C, –40 °F

IMPORTANT!

Modules may be mounted at any angle from horizontal to vertical. Select the 
appropriate orientation to maximize sunlight exposure.  

In order to prevent water from entering the junction box, which could present 
a safety hazard, modules should not be mounted such that the front/top glass 
faces downward (e.g.,  on a tracking structure that positions the module with 
the junction box facing skyward during sleep mode).

Clearance between the module frames and structure or ground is required to 
prevent wiring damage and allows air to circulate behind the module.

When installed on a roof, the module shall be mounted over a fire- resistant 
roof covering rated for the application.

The module is only guaranteed for use when its factory frame is fully intact. 
Do not remove or alter the module frame. Creating additional mounting holes 
may damage the module and reduce the strength of the frame.

Modules may be mounted using the following methods only:
1) 

Frame Holes

: Secure the module to the structure using the factory moun-

ting holes. Stainless steel bolts, with nuts, washers, and lock washers are 
recommended per module.  

2) 

Pressure Clamps or Clips

: Mount the module with the clips on the side 

frame of the module.  The side frames are attached to the longer sides of the 
module. Installers should ensure the clamps are of sufficient strength to allow 
for the maximum design pressure of the module.  Clips and clamps are not 
provided by Phaesun.

3) 

End Mount

: End mounting is the capture mounting of the length of the 

module’s end frame to a supporting rail.  The end frames are on the shorter 
sides of the module.  The end-mounting rail and clips or clamps must be of 
sufficient strength to allow for maximum design pressure of the module. 
Verify this capacity with the mounting system vendor before installation.

5.2 Installation

6.0 Maintenance

7.0 Contact to Phaesun

Inspect all modules annually for safe electrical connections, sound mechanical 
connection and freedom from corrosion. Periodically clean the module surface 
with water and a soft cloth or sponge. Fingerprints may be removed with 
standard glass cleaner. Do not use harsh cleaning materials such as scouring 
powder, steel wool, scrapers, blades or other sharp instruments to clean the 
glass surface of the module.  Use of such materials will invalidate the product 
warrant.