Cooling Kit Phaesun Direct Cool 140 DC

600419 • DE/EN • 09/2020

Please read the assembly instructions before proceeding!

1.1. Safety

In order to ensure safe and faultless function of the appliance, please read and follow these points:
•Any modification of the appliance (electrical or mechanical) is not permitted.
•Electrical components (e.g. control electronics) must be protected from water and other fluids.
•The device may not be put on the side or top (e.g., during the preparation, installation, etc.). 
   The device may be inclined max. 45°.
•If the appliance was not in upright position (e.g. before installation), it must not be started the   
   next hour, because the liquid in the compressor must flow back.

1.2. Assembly and connections

•Please make sure that during installation sufficient air circulation for cooling the appliance is 
   available (ventilation grid on the back of the appliance must not be blocked).
•The appliance works with direct current (DC) with 36 Cells PV Panels(12V) direct drive (Input 
   Voltage range 10-40 V DC).  Both PV Panels must be connected in parallel to avoid excessing    
   max. input voltage. The two PV panels are to be oriented to east and west respectively to extend 
   the operation of the refrigerator in the morning and evening.After successful installation,  
   establish the electrical connection. To do so, connect the plug of the appliance with the correctly 
   polarized coupling. The cable colors have the following meaning: Red: +; Black: -
   The appliance works without electrical batteries. Instead, an integrated ice-storage delivers coo
   ling energy during night. Please let the refrigerator empty for the first 24 hours after installation. 
•Incorrect connection may cause damage of electronic system.

1.3. Maintenance

Cleaning with water and washing-up liquid and soft textile cloths or sponges is recommend. 
Afterwards, the appliance must be dried.
•Please avoid high cooling loads (more than 5 kg at once or more than 10 kg per day) to assure a 
   right operation of the direct drive refrigerator.
•Do not use caustic cleaning agents, solvents or aggressive agents. Do not use soap either (danger 
   of smell), except lighter fluid.
•Do not use hard or sharp objects.

1.4. Troubleshooting

Failures

Possible sources of error

Error removal

Appliance does not start - No Solar Radiation

- Appliance incorrectly connected
- Contacts oxidized
- Fuse defective
- Electronic system defective
- Compressor defective
- Thermostat defective

NORMAL Operation: 

The cooling energy is delivered by the integrated 

ice-storage during night while the compressor remains off.

- Check cable polarization and PV Connections
- Clean contacts
- Exchange fuse
Please contact your sales agent directly or Phaesun GmbH

No cooling

- Ambient temperature too high
- Condenser dirty
- Cooling system leaking
- Compressor defective

- Reduce ambient temperature- max. 45°C
- Clean condenser
Please contact your sales agent directly or Phaesun GmbH