PFT ROTOQUIRL II/ PFT ROTOMIXSafety - Overview - Operation - Spare parts lists
Switching off in case of an emergency
2016-08-26
37
24 Switching off in case of an emergency
In dangerous situation machine movements have to be stopped as quickly
as possible, and the power supply has to be disconnected.
Fig.
39
:Switching off - emergency
stop
DANGER!
Danger from discharged material!
Never loosen the hose couplings as long as the pressure
head is reduced! Material to be conveyed can be
discharged under pressure and cause injuries particularly to
the eyes.
Persons commissioned with the cleaning of clogged hoses
have to wear personal protective equipment (protective
goggles, gloves) for safety reasons, and to position
themselves in such a way that they cannot be hit by
discharged material. Other persons have to clear the area.
Turn the main switch to position “0”.
Fig.
40
:Pressure gauge
DANGER!
Overpressure on the machine!
When opening machine parts they can open in an
uncontrolled manner and injure the operator.
– Open the mortar hoses only when the pressure has
dropped to “0” bar.
Switch off the main switch immediately.
Secure the main switch on the cleaning machine against
restarting.
Inform the responsible person at the operational site.
If necessary,call for medical assistance and fire brigade.
Recover persons from the danger zone, initiate First Aid
measures.
Keep access routes free for emergency vehicles.
If the severity of the emergency requires it, inform the
competent authorities.
Assign specialised personnel with the troubleshooting.
WARNING!
Danger to life from premature reactivation!
On reactivation there is danger to life for all
persons in the danger zone.
– Before reactivation ensure that there are no
persons in the danger zone anymore.