background image

 

 

Operating Instructions 

Contador

 

 

Page 40 of 40 

Revision 6 

© 2019 – Pfeuffer GmbH 

 

 

Figure 30: Container increase for feed container no. 3 

11

 

Emergency 

 

 

In an emergency, disconnect the CONTADOR/CONTAFILL from the electrical supply.

 

12

 

Disassembly and disposal 

 

Disassembly may be carried out only by 

specialist personnel.

 

 

 

Disconnect the mains plug before you start disassembling. 

 

The CONTADOR/CONTAFILL must be disposed of in accordance with the statutory local 

environmental regulations (Waste Electrical and Electronic Equipment Directive 

2012/19/EU). 

 

Hazardous waste 

Oils, cleaning agents, contaminated cleaning tools (brushes, cloths etc.) must be 

disposed of in accordance with the local directives and whilst complying with the 

information provided by the manufacturer in the safety data sheets. 

 

3

1

2

3

4

5

6

7

Item  Designation 

Storing container 

Clip angle 

Outlet funnel 

Feed container no. 3 

CONTADOR Seed counter 

CONTAFILL empty housing 

Collecting pan 

Summary of Contents for Contador

Page 1: ...97318 Kitzingen GERMANY Phone 49 9321 9369 0 Fax 49 9321 9369 50 info pfeuffer com Revision 6 25 04 2019 www pfeuffer com Translation of the original operating instructions Operating Instructions Seed...

Page 2: ...ing Copyright This document is not allowed to be communicated or duplicated utilised without express permission which also applies to communicating its content Offenders are liable to the payment of d...

Page 3: ...eral safety instructions 12 2 6 Safety tests 13 2 7 Residual dangers in connection with the CONTADOR 13 2 8 Switch off procedure 13 3 Technical data 14 3 1 CONTADOR 14 3 2 CONTAFILL accessories 14 3 3...

Page 4: ...28 7 10 Feed acceleration 28 7 11 Acoustic signal beeper 28 7 12 Changing the RS232 parameters optional 28 7 13 Sending counter via RS232 interface optional 29 7 14 Emptying the sample 29 7 15 Switch...

Page 5: ...for damage caused by improper use The operating company is solely responsible for any damage resulting from this The CONTADOR may be put into operation only once it has been established that all the s...

Page 6: ...ssessment and risk reduction DIN EN 60204 1 2006 Safety of machinery Electrical equipment of machines Part 1 General requirements DIN EN 61010 1 2011 Safety requirements for electrical equipment for m...

Page 7: ...completed machine may be put into operation only if it has been stated that the machine into which the uncompleted machine has to be incorporated does comply with the requirement of the machine direc...

Page 8: ...ng categories of danger notes and explanations of symbols Pictogram SIGNAL WORD Type of danger and its source Possible consequence of failure to comply Measure to guard against the danger DANGER This...

Page 9: ...ons apply only for the machine whose type designation is specified on the title page The type plate with the type designation can be found on the bottom of the CONTADOR It is important that the correc...

Page 10: ...r and also serves as the EMERGENCY OFF function It is located on the rear of the device Inspection Interval Method m V The connector for the mains cable C19 C20 coupler is located on the back of the d...

Page 11: ...impair safety 6 The operating personnel must be provided by the owner with appropriate protective equipment in accordance with legal requirements and the material to be processed 7 The owner must issu...

Page 12: ...y BGV A 3 Electrical systems and equipment DGUV Association of German Statutory Accident Insurance Safety of work equipment protective equipment and maintenance Product disposal waste legislation Mate...

Page 13: ...and protective measures have been tested 2 7 Residual dangers in connection with the CONTADOR During all work on electrically operated components pay attention to dangers from electrical current 2 8 S...

Page 14: ...llow green in the mains cable Internal fuse 800 mA T slow blow glass microfuse 5x20 mm Mains cable With removable supply cable C19 C20 coupler 10 A 250 V Installation regulations Configured according...

Page 15: ...t and packaging Systems and machines supplied by the Pfeuffer GmbH will be carefully checked and packaged prior to dispatch however damage during transport cannot be excluded Incoming inspection Use t...

Page 16: ...r with the PE foam pads Pay attention to the weight of 16 kg Figure 6 Remove the PE foam pads Place the CONTADOR on a flat surface Carefully remove the two PE foam pads Pick up the original packaging...

Page 17: ...feed container is adjusted according to the grain size The machine automatically detects the feed container container no 1 for rape seeds and fine seeds container no 2 for grain sunflower seeds and ry...

Page 18: ...NTWA can be supplied on request must be indicated on your CONTADOR order The control is done by means of commands in single ASCII characters Configuration of the 25 pin D Sub socket at the rear panel...

Page 19: ...of the operating personnel Connect the supplied mains cable to the CONTADOR using the connector C19 C20 coupler Connect the plug of the mains cable to a suitably earthed socked with protective earth...

Page 20: ...1 Countersunk head screw M4x12 mm 2x 2 Shaft holder 3 Guide shaft 2x 4 Carousel 5 Platform Figure 11 Carousel for bags and bottles Item Designation 6 U shaped holder for bags 7 Knurled nut 8 Eccentric...

Page 21: ...haped holders on the platform are fastened with plastic countersunk expanding rivets Push out the countersunk expanding rivets and keep all individual parts in a safe place Figure 14 Countersunk expan...

Page 22: ...the embossed arrow are at the front To remove turn the carousel to the left respectively to the right to loosen the carousel from the locking position 6 2 4 Electrical connections The CONTADOR Seed c...

Page 23: ...Steuerung D Lamp Container missing Beh lter fehlt 7 2 Switch on CONTADOR Switch on the CONTADOR via the main switch position I on the back of the device The system message CONTADOR is displayed in the...

Page 24: ...menu starts Place the desired feed container on the CONTADOR Make sure the area is clean The CONTADOR automatically detects the feed container Refer to chapter 7 4 for selecting the container Insert...

Page 25: ...a rubberized insert article number see chapter 10 Clean after counting carefully the feed container e g blow out with compressed air the outlet with spirit alcohol to avoid blockage When counting othe...

Page 26: ...ields by means of the specified keyboard combinations Keyboard combinations Parameters Setting with the buttons Possible settings Factory settings Preset 1 99950 0 Count 0 99950 0 Size 3 150 or for au...

Page 27: ...he instrument partly disregards foreign elements dust additions of a smaller diameter i e grains which are considerably smaller than the product to be counted are not considered A rape seed among a pe...

Page 28: ...ated on the display As soon as the calculated preset value is reached the feeder stops and the minus symbol instead of the arrow symbol appears in the display As preset value the originally set value...

Page 29: ...nic sensor enables the machine to automatically detect whether or not a bag or bottle is positioned in the filling position of the carousel If no container is located at the appropriate position the c...

Page 30: ...d combination leads to the display of the operating mode Select the 1 cycle operating mode with the arrow buttons Press the button to exit the entry Press the button to start the filling process The c...

Page 31: ...tching on the CONTADOR 9999 maximum is preset automatically and this means continuous filling process Select the operating mode in the CONTADOR menu The keyboard combination leads to the display of th...

Page 32: ...s for carrying out cleaning and maintenance work are based on one shift working 8 hour day 22 days month 12 months year d Daily y Every three months w Weekly y Every six months m Monthly y Every year...

Page 33: ...roducts it is necessary to clean the light barrier as required Remove the feed container and the drawer Carefully place the CONTADOR on its side Figure 23 Bottom side of CONTADOR Figure 24 Outlet funn...

Page 34: ...ew the glass microfuse Insert the plug connection back into the power switch The CONTADOR is ready for operation Figure 26 Renewal of the internal fuse Item Designation 1 Power switch 2 Pull out plug...

Page 35: ...trical electronic or mechanical maintenance Appropriate tools and test instruments must be provided to these personnel If the specified measures do not prove successful contact Pfeuffer GmbH It is imp...

Page 36: ...e electronics may be defective Have the mains voltage checked by an electrician Checked by Pfeuffer GmbH The result of the count is wrong The speed is too high The slider on the feed container is set...

Page 37: ...issing The device switches off automatically after it has found 10 times no bag for filling Place bags or bottles The carousel cannot be turned by the arrow key The connection cable to the CONTAFILL i...

Page 38: ...wer 3110 0040 Cleaning brush 3190 0027 The following articles are available as accessories for the CONTADOR Feed container no 1 for rape seeds fine seeds 2410 0101 Feed container no 1 in high design 2...

Page 39: ...positions 2410 0502 CONTAFILL empty housing standard height see figure 30 item 6 2410 0700 CONTADOR CONTAFILL connection cable 2410 2050 The following articles are available as accessories for the CON...

Page 40: ...DOR CONTAFILL must be disposed of in accordance with the statutory local environmental regulations Waste Electrical and Electronic Equipment Directive 2012 19 EU Hazardous waste Oils cleaning agents c...