![Pfeiffer TC400 Operating Instructions Manual Download Page 11](http://html.mh-extra.com/html/pfeiffer/tc400/tc400_operating-instructions-manual_1534853011.webp)
11
Connection "RS485"
6
Connection "
RS485
"
6.1 Connections
A Pfeiffer Vacuum display and control panel (DCU
or
HPU)
or
an external PC can be
connected to the electronic drive unit via the connection designated "RS485". The
interface is electrically isolated from the maximum supply voltage of the electronic
drive unit. The electrical couplings are optically decoupled internally.
6.2 Connecting Pfeiffer Vacuum display and control units or PC
Use the connection cable supplied with the control panel or from the range of
accessories.
The connection of respectively one external operating unit is possible on the in-
terface RS 485.
A USB interface (PC) can be connected via the USB/RS485-converter.
Fig. 3:
Optional connection possibilities for interface RS485
Designation
Value
Serial interface
RS485
Baud rate
9600 Baud
Data file word length
8 bit
Parity
keine (no parity)
Start bits
1
Stop bits
1..2
1
2
3
4
5
Pin
Assignment
1
RS485: D+
2
+24 V output, loadable with
≤
210 mA
3
GND
4
RS485: D-
5
not connected
DCU 002
DCU 310 / 400
TC 400
HPU 001
RS485
USB/RS485-converter