background image

3

5 (2x)

2

4

1

Fig. 5:

Example: Assembling a heating sleeve on the HiPace 1200

1 Pump housing

4

Heating relay box

2 Interior hexagon socket screw

5

"Hot surface" warning sticker

3 Heating sleeve

Assembling a heating sleeve

1. Carefully bend out the heating sleeve at the outer clamping strap.
2. Push the sleeve onto the cylindrical section of the pump housing, either from above or from the 

side, depending on the respective installation situation.

3. Make sure that the heater bands are not deformed and that the sleeve is sitting flush against the 

housing.

4. Secure the heating sleeve onto the housing with the interior hexagon socket screw.
5. Attach the "Hot surface" sticker to the pump housing.
6. Install suitable screening sheets as protection in case the irradiated heat input exceeds the per-

missible maximum values.

Fixing screw 

thread

Tightening torque in 

cold condition

Tightening torque for 

bakeout

One-time retightening 

after cooling

M5

6 Nm

7 Nm

7 Nm

M6

11 Nm

12 Nm

12 Nm

Tbl. 3:

Tightening torques for heating sleeve fixing screws

Connecting the control line

1. Connect the accessory control line to the electronic drive unit using the corresponding accessory 

connection, and screw the plug tight.

2. Check the specification in the configuration of the respective turbopump 

"accessory A1"

.

Connecting to the mains power supply

► Make sure that the supply voltage is correct.
► Connect the plug on the mains cable to a suitable socket.
► Always ensure a secure connection to the earthed conductor (PE), protection class I.

Installation

11/20

Summary of Contents for PM 061 360-T

Page 1: ...OPERATING INSTRUCTIONS EN Translation of the Original HIPACE Heating sleeve...

Page 2: ...vacuum de Further operating instructions from Pfeiffer Vacuum can be found in the Download Center on our website Disclaimer of liability These operating instructions describe all models and variants o...

Page 3: ...6 2 1 General safety information 6 2 2 Safety instructions 6 2 3 Safety precautions 6 2 4 Limits of use of the product 7 2 5 Proper use 7 2 6 Foreseeable misuse 7 2 7 Personnel qualification 7 3 Produ...

Page 4: ...M HiPace 350 HiPace 400 HiPace 450 HiPace 700 HiPace 700 M HiPace 800 HiPace 800 M HiPace 1200 HiPace 1500 HiPace 2300 1 2 Target group This operating instructions is intended for persons who install...

Page 5: ...W 12 2019 Rating plate example The rating plate is located on the relay box Warning hot surface This sticker warns of injuries caused by high temperatures in case of touching without protection during...

Page 6: ...dicate important information about the product or about this docu ment 2 2 Safety instructions All safety instructions in this document are based on the results of the risk assessment Where applica bl...

Page 7: ...otection category IP54 Cooling Water cooling is essential for the turbopump Relative air humidity 85 not condensing Tbl 2 Permissible ambient and operating conditions 2 5 Proper use Use the heating sl...

Page 8: ...work with the product 4 Before starting work make sure that the commissioned personnel have read and understood these operating instructions and all applicable documents in particular the safety main...

Page 9: ...g sleeve 1 Interior hexagon socket screw 3 Relay box 2 Heating sleeve 3 2 Identifying the product To ensure clear identification of the product when communicating with Pfeiffer Vacuum always keep all...

Page 10: ...spective type Do not exceed the maximum permissible irradiated thermal output If necessary install screening sheets information available upon request Required tools Allen key size 4 or 5 Calibrated t...

Page 11: ...ker to the pump housing 6 Install suitable screening sheets as protection in case the irradiated heat input exceeds the per missible maximum values Fixing screw thread Tightening torque in cold condit...

Page 12: ...ambient conditions Important settings and function related variables programmed ex factory as parameters in the vacuum pump electronic drive unit Each parameter has a three digit number and a descript...

Page 13: ...ty You can find more detailed information and addresses on our homepage in the Pfeiffer Vacuum Service section You can obtain advice on the optimal solution for you from your Pfeiffer Vacuum represent...

Page 14: ...duct in suitable stable transport containers only e Maintain applicable transport conditions ERKL RUNG KONTAMINIERUNG 6 Attach the contamination declaration to the outside of the packag ing 7 Now send...

Page 15: ...Power consumption of heating sleeve max 40 W 40 W 40 W Plug M8 M8 M8 Nominal diameter 82 mm 82 mm 82 mm Tbl 6 Technical data heating sleeve for HiPace 80 with TC 110 PB screened Classification Heating...

Page 16: ...Heating sleeve for Hi Pace 400 700 800 208 V AC Heating sleeve for Hi Pace 400 700 800 115 V AC Order number PM 061 369 T PM 061 370 T PM 061 371 T Pump HiPace 400 700 800 HiPace 400 700 800 HiPace 40...

Page 17: ...30 V AC 208 V AC 115 V AC Power consump tion of heating sleeve max 120 W 120 W 120 W Plug M12 M12 M12 Nominal diame ter 184 mm 184 mm 184 mm Tbl 13 Technical data heating sleeve for HiPace 400 HiPace...

Page 18: ...screened for Hi Pace 2300 208 V AC Heating sleeve screened for Hi Pace 2300 115 V AC Power consumption of heating sleeve max 450 W 450 W 450 W Plug M12 M12 M12 Nominal diameter 311 mm 311 mm 311 mm Tb...

Page 19: ...oltage 2014 35 EC Restriction of the use of certain hazardous substances 2011 65 EU Restriction of the use of certain hazardous substances delegated directive 2015 863 EU Harmonized standards and appl...

Page 20: ...PT0233 ed D Date 2003 P N PT0233BEN...

Reviews: