Fig. 13:
Connection example with PTC thermistor tripping unit
U
S
Control voltage
T1 – T3
PTC resistor sensor
S
1
OFF button
H1
Tripping indicator
S
2
ON button
M
Motor, 3-phase
S
3
RESET button
1)
For devices with two relay outputs only
K1
Contactor
2)
For MSR type (model) only
F1 – F4
Fuses
3)
Only for order no.: P 4768 052 FQ
Procedure
► When connecting the vacuum pump, always adhere to the direction of rotation, regardless of the
illustration in the wiring diagram.
– The sense of rotation arrow on the vacuum pump indicates the rotation direction.
► After shut-down, switch the tripping unit back on manually via the installed RESET button or via
the external RESET S3.
– Switching on mains detected as automatic RESET.