► Use only accessory parts recommended by Pfeiffer Vacuum.
► Use the vacuum pump to convey potentially explosive atmospheres in accordance with the label-
ing.
► Operate the vacuum pump within the application limits of the product
and in compliance with the technical data.
► Observe the corresponding safety measures
(see chapter “Safety measures”, page 17)
.
2.7 Foreseeable improper use
Improper use of the product invalidates all warranty and liability claims. Any use that is counter to the
purpose of the product, whether intentional or unintentional, is regarded as improper use; in particular:
● pumping media which are corrosive to or too aggressive for the vacuum pump materials
● pumping media that introduce an ignition source to the suction chamber
● pumping pyrophoric or corrosive media, or media releasing FKM
● pumping media prone to spontaneous, specific exothermic reactions
● pumping media that contain impurities such as particles, dust, or condensate
● pumping media that can condense or cause adhering deposits to form in the suction chamber
● pumping media with a propensity to sublimation
● pumping pressurized media (> atmospheric pressure)
● pumping fluids
● pumping radioactive media
● using the vacuum pump outside the specified area of application
● using the vacuum pump in systems in which sporadic loads and vibrations or periodic forces act
on the unit
● using the vacuum pump in strong electrical, magnetic, or electromagnetic fields
● using for media being pumped for which the ignition temperature drops below a temperature limit
of T4, at pressures greater than atmospheric pressure
● using pipes to lift the vacuum pump
● using accessories or spare parts not listed in this manual
● using the vacuum pump as a climbing aid
● painting the vacuum pump, motor and accessories
● using operating fluids that have not been approved by Pfeiffer Vacuum
● using mineral-based operating fluids such as P3, with an oxygen concentration > 21 %.
Mineral-based operating fluids are combustible and ignite at high temperatures, and when they
come into contact with pure oxygen. These operating fluids oxidize heavily and thus lose their lu-
bricating capacity.
2.8 Personnel qualification
The work described in this document may only be carried out by persons who have appropriate profes-
sional qualifications and the necessary experience or who have completed the necessary training as
provided by Pfeiffer Vacuum.
Training people
1. Train the technical personnel on the product.
2. Only let personnel to be trained work with and on the product when under the supervision of
trained personnel.
3. Only allow trained technical personnel to work with the product.
4. Before starting work, make sure that the commissioned personnel have read and understood
these operating instructions and all applicable documents, in particular the safety, maintenance
and repair information.
2.8.1 Ensuring personnel qualification
Specialist for mechanical work
Only a trained specialist may carry out mechanical work. Within the meaning of this document, special-
ists are people responsible for construction, mechanical installation, troubleshooting and maintenance
of the product, and who have the following qualifications:
● Qualification in the mechanical field in accordance with nationally applicable regulations
● Knowledge of this documentation
Safety