Operating instructions PY L-S-TL/ PY L-S-TLA
09/2020
Page 6 /7
086200016b
en
6.2 Electrical connection
➢
Circuit board in lower part:
Connecting terminal (
X1
)
X1
Operating voltage connection
X2
Plug connection light for combined
operation with sounder.
X3
Plug connection sounder
X4
Plug connection 1
st
stage
X5
Plug connection 2
nd
stage
X6
Plug connection 3
rd
stage
AC: DC:
Operating voltage connection
L/
N/
+
-
1
st
stage
2
nd
stage
3
rd
stage
Note
: Devices with DC voltage are equipped with reverse polarity protection. No function if the polarity of the
connections is reversed.
6.3 Setting the operating modes
Circuit board in the lens:
S1
Selection of operating mode
Light intensity control
Flashing light: 10
– 100%
Blinking- / Continuous light:
45
– 100%
S1
Operating mode
1
2
3
OFF OFF OFF
Flashing light 1 Hz
*
OFF OFF ON
Flashing light 0.75 Hz
OFF ON OFF
Continuous light
OFF ON ON
Blinking light 1 Hz
ON OFF OFF
Flashing light 2 Hz
ON OFF ON
Blinking light 2 Hz
ON ON OFF
Flashing light 0.1 Hz
ON ON ON
Flashing light 0.5 Hz
*
Factory setting