![Pfaff select 1520 Service Manual Download Page 65](http://html1.mh-extra.com/html/pfaff/select-1520/select-1520_service-manual_1534623065.webp)
63
33. Adjustment of bobbin case position finger
Requirement:
The clearance between the position finger and the bottom of the groove in the bobbin case base must be
0.7 mm.
Check:
z
It must be possible to insert clearance gauge (00-880133-01) with ease but without play between the
position finger and the bottom of the groove in the bobbin case base (fig. 68).
Adjustment:
z
Loosen the two screws 114.
z
Insert clearance gauge.
z
Press bobbin case position finger 113 against the gauge at an angle of 90 degrees.
z
Tighten the two screws 114.
Cross-check:
z
As described under "Check".
Summary of Contents for select 1520
Page 1: ...Service Manual 1st Release August 2001 ...
Page 2: ......
Page 14: ...12 Notes ...
Page 17: ...15 ...
Page 19: ...17 ...
Page 23: ...21 ...
Page 25: ...23 ...
Page 31: ...29 Notes ...
Page 35: ...33 ...
Page 41: ...39 Cross check z As described under Check ...
Page 43: ...41 Notes ...
Page 45: ...43 ...
Page 47: ...45 ...
Page 53: ...51 ...
Page 59: ...57 Cross check z Carry out a visual check at straight and zigzag stitch settings ...
Page 63: ...61 ...
Page 67: ...65 ...
Page 71: ...69 ...
Page 73: ...71 ...
Page 79: ...77 ...
Page 81: ...79 ...
Page 83: ...81 ...
Page 85: ...83 ...
Page 87: ...85 ...
Page 89: ...87 ...
Page 91: ...89 ...
Page 100: ...98 ...
Page 102: ...100 Notes ...
Page 103: ...101 Notes ...
Page 104: ...102 Notes ...
Page 105: ...103 Notes ...