![Pfaff select 1520 Service Manual Download Page 39](http://html1.mh-extra.com/html/pfaff/select-1520/select-1520_service-manual_1534623039.webp)
37
17. Adjustment of needle penetration in needle plate slot
Requirement:
At straight stitch setting with needle position "center" the needle must be exactly in the center of the
needle plate slot (fig. 30).
Check:
z
Remove presser foot.
z
Insert a new needle.
z
Set stitch width adjustment dial 70 to "0" (fig. 32).
z
Set needle position adjustment dial 79 to "center".
z
Turn the handwheel and check the centered position of the needle.
Adjustment:
z
Loosen the three screws 75 on the zigzag-stitch unit by just 1/8 of a turn.
z
Turn the handwheel until the needle point is level with the surface of the needle plate (fig. 31).
z
Move the zigzag-stitch unit to the left or right until the needle is exactly in the center of the needle plate
slot (fig.32).
Note:
The zigzag-stitch unit should now be parallel to the arm shaft and clear it by 3.0 mm.
z
Tighten the three screws 75.
Cross-check:
z
The needle must be exactly in the center of the needle plate slot.
Summary of Contents for select 1520
Page 1: ...Service Manual 1st Release August 2001 ...
Page 2: ......
Page 14: ...12 Notes ...
Page 17: ...15 ...
Page 19: ...17 ...
Page 23: ...21 ...
Page 25: ...23 ...
Page 31: ...29 Notes ...
Page 35: ...33 ...
Page 41: ...39 Cross check z As described under Check ...
Page 43: ...41 Notes ...
Page 45: ...43 ...
Page 47: ...45 ...
Page 53: ...51 ...
Page 59: ...57 Cross check z Carry out a visual check at straight and zigzag stitch settings ...
Page 63: ...61 ...
Page 67: ...65 ...
Page 71: ...69 ...
Page 73: ...71 ...
Page 79: ...77 ...
Page 81: ...79 ...
Page 83: ...81 ...
Page 85: ...83 ...
Page 87: ...85 ...
Page 89: ...87 ...
Page 91: ...89 ...
Page 100: ...98 ...
Page 102: ...100 Notes ...
Page 103: ...101 Notes ...
Page 104: ...102 Notes ...
Page 105: ...103 Notes ...