Adjustment
40
6
604
Cutting:
C
OFF - ON
ON
ON = forwards after semi end backtack
OFF = in reverse too
605
Speed display:
B
OFF - ON
OFF
ON = on / OFF = off
606
Speed level 1 (min.) [min
-1
]
B
30 - 550
180
607
Speed level 12 (max.) [min
-1
]
B
300 - 5000 4500
609
Cutting speed [min
-1
]
B
60 - 500
180
618
Reverse turning angle
B
OFF - ON
OFF
ON = on / OFF = off
624
Start inhibitor: ON = on / OFF = off
C
OFF - ON
ON
642
Presser foot time from switch-on
C
10 - 50
50
to tension reduction (timing)
651
Automatic lowering of presser foot:
C
OFF - ON
ON
ON = on / OFF = off
660
Bobbin thread monitor:
A
0 - 2
1
0 = off, 1 = on
2 = bobbin thread reverse counter on
668
Thread wiper = 1,
B
0 - 2
2
Thread clamp = 2, 0 = off
7
700
Logical zero mark [increments]
B
0 - 127
0
702
Needle position (needle lowered)
B
0 - 30
15
703
Needle position (take-up lever raised)
B
100 - 127
113
705
Needle position (end of cutting signal)
B
80 - 127
98
706
Needle position (start of cutting signal)
B
40 - 80
68
707 Needle position
B
40 - 80
70
(start thread tension release)
710
Needle position
B
80 - 127
106
(needle raised without cutting)
715
Operating time of thread wiper [ms]
B
0 - 2550
120
718
Moment of
B
0 - 100
0
standstill brake (rest brake)
Group
Parameter
S
et
ting
range
Description
S
et value
User level