Adjustment
13 - 67
13
.09.03
List of parameters
The operator has free access to the "100" parameters. Parameters "200" - "800"
can only be changed after entering a code number and may only be changed by
authorised personnel.
Group Parameter
Description
Setting
Set
range
value
1
102
Reversing
OFF - ON
OFF
113
Beep tone for section change
OFF - ON
OFF
114
Max. speed forwards at each
OFF - ON
OFF
pedal position
2
201
Machine configuration
3 - 7
-
6 = 3822-2/42
7 = 3822-2/44
209
Fullness adjustment value (keyboard)
0 - 9
0
210
Switch off edge knife
(with pedal position "-2")
OFF - ON
OFF
3
301
Position
0 - 127
0
"Needle point at top edge needle plate"
302
Position "take-up lever t.d.c."
0 - 127
113
303
Position "needle lowered"
0 - 127
on the 3822-2/42
60
on the 3822-2/44
10
304
Reversing position
0 - 127
113
305
Placement stitch position
0 – 127
7
4
401
Delay time "lift foot" (s)
0,01 – 1,50
0,02
402
Start delay after "lower foot" (s)
0,01 – 1,50
0,15
404
Time for cleaning thread monitor (s)
0,01 - 1,50
0,25
5
501
Maximum speed
100 – 3500
3200
504
Speed soft start
100 – 3500
1500
505
Soft start stitches
0 – 15
0
7
701
P-quota speed controller
1 – 50
30
702
I-quota speed controller
0 – 100
50
703
P-quota position controller
1 – 50
20
Summary of Contents for 3822-2/42
Page 147: ...15 3 91 191 494 95 Page 1 Version 01 09 05 Circuit diagrams...
Page 148: ...15 4 Circuit diagrams Version 01 09 05 91 191 494 95 Page 2...
Page 149: ...15 5 91 191 494 95 Page 3 Version 01 09 05 Circuit diagrams PFAFF PFAFF PFAFF PFAFF PFAFF...
Page 150: ...15 6 Circuit diagrams Version 01 09 05 91 191 494 95 Page 4...
Page 151: ...Notes...