![Pfaff 333-712/02 Adjustment Manual Download Page 12](http://html1.mh-extra.com/html/pfaff/333-712-02/333-712-02_adjustment-manual_1534297012.webp)
Adjustment
12
Fig. 13 - 07
13
.04.07
Switching off the needle thread tension release
O
Turn the handwheel until the tension discs are closed.
O
Align the lever
1
according to
rule
1.
O
Turn the stop
2
(nut
3)
according to
rule
2.
The magnet lift is factory set to
1 mm
.
Setting on the nut
5
(lock nut
6).
Rule
1. There should be a clearance of approx.
0.5 mm
between the lever
1
and the tension
disc
4
when the tension discs are closed.
2. The nut
5
should abut the stop
2
in the basic position of the solenoid
7.
0.5 mm
2
1
3
4
5
7
7
6
1