Adjustment
13.
07.03
Radial position of the tripping lever
Requirement
With the tripping lever
3
in resting position, there must be a clearance of
0.3 mm
between its roller and the circumference of the control cam
4
.
Fig. 13 - 35
●
Bring the needle bar to BDC.
●
Move solenoid carrier
1
( nuts of screws
2
) in accordance with the
requirement.
4
3
0.3 mm
2
1
13 - 40