Parameter Settings
20
9
985
Switch on angle for thread trapper
B, C
0 -255
67
986
Switch off angle for thread trapper
B, C
0 -255
206
989
Thread trapper at beginning of seam
B, C
0 - 2
0
1 = yes, 0 = no
10
1001
Stepping motor starting angle
B, C
0 - 255
1181, 3701
25
1183
170
5483
144
1003
Feed roller radius
C
5 - 50
15
11
1100
Operating mode stepping motor 1
C
0 - 2
1
1101
Rotation direction stepping motor 1
C
0 - 1
0
1 = anti-clockwise, 0 = clockwise
1102
Stepping mode stepping motor 1
C
0 - 4
3
1 = full-step, 2 = half-step,
3 = quarter step, 4 = eighth step
1103
Maximum current stepping motor in %
C
0 - 100
50
1104
Reducing current stepping motor in %
C
0 - 50
30
1105
Stepping motor 1, start-stop-time
C
10 - 4000
180
(time for 1
st
step at start-stop-speed)
1106
Maximum speed stepping motor 1
C
10 - 4000
843
1107
Acceleration in % of max. speed on
C
1 - 50
28
stepping motor 1
1108
Number of brake steps of stepping motor 1
C
1 - 50
5
1160
Feed motion compensation at beginning of seam
A, B, C
0 - 99
20
The standard values listed in the table are basic settings, which can be
altered if necessary.
Further parameters are contained in the Motor Instruction Manual
V
See Chapter 3 Specifications
in the machine Instruction Manual.
* Adjustment see Chapter 3.01 Basic position of the machine drive unit.
Group
Parameter
Description
Standard value
Adjustment
range
Access level
Summary of Contents for 1180 series
Page 25: ...25 91 191 504 95 Page 1 Version 03 07 06 Circuit diagrams...
Page 26: ...26 Circuit diagrams Version 03 07 06 91 191 504 95 Page 2...
Page 27: ...27 91 191 504 95 Page 3 Version 03 07 06 Circuit diagrams...
Page 29: ...29 91 191 503 95 Page 1 Version 30 06 06 Circuit diagrams...
Page 30: ...30 Circuit diagrams Version 30 06 06 91 191 503 95 Page 2...
Page 31: ...31 91 191 503 95 Page 3 Version 30 06 06 Circuit diagrams...