Installation
The site of installation should be at least 50 cm away
from another light because heat radiated from it may
activate the system. To obtain the specified reach of
8 m, the sensor should be installed at a height of
approx. 1.7 – 2 m.
Connecting the mains supply lead (see illustration)
The main supply leads is a 2 to 3-core cable:
L
= phase conductor (usually black or brown)
N
= neutral conductor (usually blue)
PE
= protective earth conductor (green/yellow)
Principle
The integrated high-performance infrared sensor is
equipped with a double 360° sensor that detects the
invisible heat emitted by moving objects (persons,
animals etc.).
The heat detected in this way is converted electronic-
ally into a signal that switches the light on automatic-
ally. Heat is not detected through obstacles, such as
walls or panes of glass. Heat radiation of this type
will, therefore, not trigger the sensor. The unit
- 11 -
System components
Lamp arm
Wall mount screw
Wall mount
Mains power supply lead, concealed
Mains power supply lead, surface-mounted
Glass shade locking screw
Installation instructions
Dear Customer,
Congratulations on purchasing your new STEINEL
SensorLight and thank you for the confidence you
have shown in us. You have chosen a high-quality
product that has been manufactured, tested and
packed with the greatest care.
GB
Safety warnings
■
Disconnect the power supply before attempting any
work on the unit.
■
The electrical connection lead must be dead during
installation. Therefore, switch off the power first and
use a voltage tester to make sure the wiring is off
circuit.
Please familiarise yourself with these instructions
before attempting to install the SensorLight because
prolonged reliable and trouble-free operation will only
be ensured if it is fitted properly.
We hope your new STEINEL SensorLight will bring
you lasting pleasure.
■
Installing the SensorLight involves work on the mains
voltage supply. This work must therefore be carried
out professionally in accordance with applicable
national wiring regulations and electrical operating
conditions.
(
D
- VDE 0100,
A
-ÖVE-EN 1,
-SEV 1000)
Glass shade
Sensor unit (removes for ease of setting functions)
Engagement lug for removing sensor unit
Time setting
Twilight setting
Programme setting
achieves a coverage angle of 360° with an aperture
angle of 90°. Coverage below the sensor ensures a
sneak-by guard.
Important:
The most reliable way of detecting motion
is to install the SensorLight with the sensor aimed
across the direction in which a person would walk and
by ensuring that no obstacles (such as trees and walls,
for example) obstruct the line of sensor vision. Reach
is limited when walking directly towards the light.
If you are in any doubt, identify the conductors using
a voltage tester; switch off the current again. Connect
phase (
L
), neutral (
N
) and protective earth (
PE
) to the
terminal block (earthing spike for L 30x S).
With lamp arms made of plastic (L 9x5 S) the protective
earth conductor (
PE, green/yellow
) can be taped off
with insulation tape.
Note:
A mains switch for switching the unit ON and
OFF may of course be installed in the power supply
lead. A mains switch is required for the manual over-
ride function (see Manual override function)
.
GB