6. Ambient conditions
- The BENNING MM P3 is intended for measurements under dry ambient
conditions,
- Maximum barometric height for measurements: 2000 m,
- Overvoltage category / installation category: IEC 60664-1/ IEC 61010-1 → 300 V
category III; 600 V category II,
- Contamination class: 2,
- Protection category: IP 30 DIN VDE 0470-1 IEC/EN 60529
IP 30 means: Protection against access to dangerous parts and protection
against solid impurities of a diameter > 2.5 mm, (3 – first index).
No protection against water, (0 – second index).
- Operating temperature and relative air humidity:
For operating temperatures from 0 °C to 30 °C: relative air humidity less than 80 %,
For operating temperatures from 31 °C to 40 °C: relative air humidity less than 75 %,
For operating temperatures from 41 °C to 50 °C: relative air humidity less than 45 %,
- Storage temperature: The BENNING MM P3 can be stored at temperatures
between - 20 °C and + 60 °C (air humidity of 0 to 80 %). During storage, the
batteries should be removed.
7.
Electrical specifications
Note: The measuring accuracy is specified as the sum of:
- a relative part of the measured value and
- a number of digits (i.e. counting steps of the last digit).
This measuring accuracy applies for temperatures from 18 °C to 28 °C and a relative
air humidity less than 80 %.
7.1 DC voltage ranges
(Switch setting: V
DC
mV
DC
)
The input resistance is 10 MΩ.
Measuring range Resolution
Measuring accuracy
Overload
protection
400 mV
0.1 mV
± (0.7 % of the measured value + 5 digits)
600 V
DC
4 V
1 mV
± (0.6 % of the measured value + 2 digits)
600 V
DC
40 V
10 mV
± (0.6 % of the measured value + 2 digits)
600 V
DC
400 V
100 mV
± (0.6 % of the measured value + 2 digits)
600 V
DC
600 V
1 V
± (0.7 % of the measured value + 5 digits)
600 V
DC
7.2 AC voltage ranges
(Switch setting: V
AC
, Hz, %)
The input resistance is 10 MΩ in parallel 100 pF.
Measuring range Resolution
Measuring accuracy *
1
within the
frequency range 50 Hz - 500 Hz
Overload
protection
400 mV
0.1 mV
± (1.5 % of the measured value + 5 digits)
600 V
eff
4 V
1 mV
± (0.9 % of the measured value + 5 digits)
600 V
eff
Summary of Contents for BENNING MM P3