SERVICE SCHEDULE AND COMMISSIONING
7
Reproduction or translation, even partial, is forbidden without the written consent of Peugeot Motocycles
Battery preparation (Except battery without maintenance)*.
Remove the battery.
Remove the 6 filler caps and the vent plug.
Fill with electrolyte to the level marked "UPPER LEVEL".
Electrolyte: (35% sulfuric acid = 1.28 g/cm
3
)
1 litre can P/N 752740.
5 litre can P/N 752741.
Leave the battery to stand for around half an hour.
Top up if necessary.
Charge the battery for at least 2 hours with a current of 0.4A.
Refit the battery and connect the vapour vent pipe.
Connect the red wire lug to the battery's + terminal, and the green wire lug to the battery's - terminal.
Then, the battery level should be topped up if necessary, after fully charging, using distilled water only.
Checks before handing over to the customer.
Check the wheel nuts are tight.
Check nuts and bolts are tight.
Check brake adjustment and efficiency.
Check the tyre pressures cold.
Check operation of the lights, flashers, horn, and brake light.
Check the different warning lights work.
Carry out a road test with the machine.
* Depending on equipment.
Summary of Contents for BLASTER
Page 1: ...Sales division Technical network leadership WORKSHOP MANUAL ...
Page 23: ......