Windscreen/tailgate wipers inoperative, or
unsatisfactory in operation
Wipers fail to operate, or operate very slowly
m
m
Wiper blades stuck to screen, or linkage seized or binding
(“Weekly checks” and Chapter 12).
m
m
Blown fuse (Chapter 12).
m
m
Cable or cable connections loose, broken or disconnected
(Chapter 12).
m
m
Faulty relay (Chapter 12).
m
m
Faulty wiper motor (Chapter 12).
Wiper blades sweep over too large or too small an area of
the glass
m
m
Wiper arms incorrectly positioned on spindles (Chapter 12).
m
m
Excessive wear of wiper linkage (Chapter 12).
m
m
Wiper motor or linkage mountings loose or insecure (Chapter 12).
Wiper blades fail to clean the glass effectively
m
m
Wiper blade rubbers worn or perished (“Weekly checks” ).
m
m
Wiper arm tension springs broken, or arm pivots seized
(Chapter 12).
m
m
Insufficient windscreen washer additive to adequately remove
road film (“Weekly checks” ).
Windscreen/tailgate washers inoperative, or
unsatisfactory in operation
One or more washer jets inoperative
m
m
Blocked washer jet (Chapter 1).
m
m
Disconnected, kinked or restricted fluid hose (Chapter 12).
m
m
Insufficient fluid in washer reservoir (Chapter 1).
Washer pump fails to operate
m
m
Broken or disconnected wiring or connections (Chapter 12).
m
m
Blown fuse (Chapter 12).
m
m
Faulty washer switch (Chapter 12).
m
m
Faulty washer pump (Chapter 12).
Washer pump runs for some time before fluid is emitted
from jets
m
m
Faulty one-way valve in fluid supply hose (Chapter 12).
Electric windows inoperative, or unsatisfactory in
operation
Window glass will only move in one direction
m
m
Faulty switch (Chapter 12).
Window glass slow to move
m
m
Regulator seized or damaged, or in need of lubrication
(Chapter 11).
m
m
Door internal components or trim fouling regulator (Chapter 11).
m
m
Faulty motor (Chapter 11).
Window glass fails to move
m
m
Blown fuse (Chapter 12).
m
m
Faulty relay (Chapter 12).
m
m
Broken or disconnected wiring or connections (Chapter 12).
m
m
Faulty motor (Chapter 11).
Central locking system inoperative, or
unsatisfactory in operation
Complete system failure
m
m
Blown fuse (Chapter 12).
m
m
Faulty relay (Chapter 12).
m
m
Broken or disconnected wiring or connections (Chapter 12).
m
m
Faulty control unit (Chapter 11).
Latch locks but will not unlock, or unlocks but will not lock
m
m
Faulty master switch (Chapter 12).
m
m
Broken or disconnected latch operating rods or levers
(Chapter 11).
m
m
Faulty relay (Chapter 12).
m
m
Faulty control unit (Chapter 11).
One solenoid/motor fails to operate
m
m
Broken or disconnected wiring or connections (Chapter 12).
m
m
Faulty solenoid/motor (Chapter 11).
m
m
Broken, binding or disconnected latch operating rods or levers
(Chapter 11).
m
m
Fault in door latch (Chapter 11).
Fault finding
REF•19
REF
Summary of Contents for 205 Cabriolet
Page 108: ...4B 8 Notes ...
Page 114: ...4C 6 Notes ...
Page 132: ...5B 8 Notes ...
Page 148: ...9 16 Notes ...
Page 160: ...10 12 Notes ...
Page 174: ...11 14 Notes ...
Page 189: ...Wiring diagrams 12 15 12 Key to wiring diagrams ...
Page 190: ...12 16 Wiring diagrams Key to wiring diagrams continued ...
Page 230: ...REF 29 REF Notes ...
Page 231: ...Left blank for manual listing pages ...