Outside faucets used to water lawns and gardens should not supply softened water. A new water line is often required to be connected to supply hard water to the inlet of
the water softener and to the outside faucets. Cut the water line between where it enters the house and before any lines that branch off to feed the hot water heater or other
fixtures in the house and as near the desired location of the water softener as possible. Install a tee fitting on the feed end of the cut pipe, and an elbow fitting on the other end.
Install piping from the tee to the inlet of the water softener and from the elbow to the outlet of the softener. To sever the water lines which branch off to feed any outside faucets,
cut the branch lines approximately two inches from the fitting on the main water line. Install an elbow on the end of the pipe nearest the outside faucet and a cap on the end
connected to the existing water line. Install piping from the tee installed on the inlet line to the water softener to the elbow installed on the pipe to the outside faucet. Following
this procedure will result in all lines in the house, with the exception of the outside faucets, but including the water heater and therefore the hot water lines, being supplied with
soft water.
NOTE
If the plumbing system is
used as the ground leg of
the electric supply, conti-
nuity should be maintained
by installing ground straps
around any nonconductive
plastic piping used in
installation.
NOTE
Before starting installation,
read page 16, Plumbing
System Clean-Up, for in-
structions on some proce-
dures that may need to be
performed first.
Facts to Remember When Planning Your Installation
1.
All installation procedures must conform to local and state or provincial plumbing codes.
2.
Outside faucets used to water lawns and gardens should not supply untreated water, replace untreated water with feed water
to the unit. If necessary to do this please install check valve, see page 14. A new water line is often required to be connected to
supply untreated water to the inlet of the water softener and to the outside faucets.
3.
Make sure the bypass is attached well to the control valve. Connect the straight or elbow connectors to the bypass with red
clips. Connect the inlet and outlet of the water softener to the plumbing of the house. The control valve must not be submitted
to temperatures above 43°C (110°F). When sweat fittings are used, to avoid damaging the control valve, solder the threaded
copper adapters to the copper pipe and then, using Teflon tape, screw the assembly into the bypass valve.
Do not use pipe thread compound as it may attack the material in the valve body.
4.
Apply Teflon Tape and Orings to the fittings
5.
Connect Softener to the house plumbing. Any solder joints near the valve must be done before connecting any piping to the
valve. Always leave at least 6” (152 mm) between the valve and joints when soldering pipes that are connected to the valve.
Failure to do this could cause damage to the valve.
6.
Drain Line connection:
Using Teflon tape, screw the 1/2” hose barb and attach oring into the drain port in the valve. Attach
1/2” drain hose (Supplied with some models and brands) to the hose barb and tighten securely with a hose clamp (Supplied
with some models and brands). Run the drain line to a floor drain or a laundry drain. Complete any necessary plumbing.
7.
Using the Allen Key (included), place the unit in the bypass position. Slowly turn on the main water supply. At the nearest cold
treated water tap nearby remove the faucet screen, open the faucet and let water run a few minutes or until the system is free
of any air or foreign material resulting from the plumbing work.
8.
Make sure there are no leaks in the plumbing system before proceeding. Close the water tap when water runs clean.
9.
Open the brine tank / cabinet salt lid and add water until there is approximately 3” (75 mm) of water in the tank. Do not add
salt to the brine tank at this time.
Determine the best location for your water softener, bearing in mind the location of your water supply lines, drain line and 120 volt AC electrical outlet. Subjecting the
softener to freezing or temperatures above 43°C (110°F) will void the warranty.