background image

10 

Customer Care Center 1-800-732-2677

To Twist the Boundary Wire 

Twisting the Boundary Wire cancels the signal and allows your pet to cross over that area 

safely (

4B

). To ensure the signal is cancelled, it is recommended that you cut and splice the 

Boundary Wire between each twisted section. The signal cannot be cancelled by running 

the wire through plastic or metal piping. Splicing shielded cable to the Boundary Wire will 

also not cancel the signal. Refer to figure (

4C

) for the correct method for twisting the wire. 

You can twist your own wire by cutting two equal lengths of Boundary Wire supplied and 

twisting them together. Anchor one end of the wires to something secure and insert the 

other end in a power drill. Pull the wire taut. The drill enables you to twist the wire quickly. 

Twist the Boundary Wire 10 to 12 times per foot to cancel the signal. Once you have 

completed your boundary layout, insert the twisted wire into the transmitter.

10  

T

wists/ft.

4B

To Splice or Repair the Boundary Wire

If you need additional Boundary Wire to expand your wire loop, you will 

need to splice the wires together. Note the locations of all splices for future 

reference.
Strip approximately 

3

8

 inch of insulation off the ends of the Boundary Wires to 

be spliced (

4D

). Make sure the copper Boundary Wire is not

TWISTED WIRES

BOUNDARY WIRE

WATERPROOF SPLICE

CORRECT

INCORRECT

4C

corroded. If the Boundary Wire is corroded, cut it back to expose clean copper wire.
Insert the stripped ends into the wire nut and twist the wire nut around the wires. Ensure 

that there is no copper exposed beyond the end of the wire nut. Tie a knot 3 to 4 inches 

from the wire nut (

4E

). Ensure that the wire nut is secure on the wire splice. 

Once you have securely spliced the wires together, open the lid of the gel-filled splice 

capsule and insert the wire nut as deeply as possible into the waterproof gel inside the 

capsule (

4F

). Snap the lid of the capsule shut (

4G

). For proper system performance, the 

splice connection must be waterproof. 
If your splice pulls loose, the entire system will fail. Make sure your splice is secure. 

Additional gel-filled splice capsules and wire nuts are available through the Customer 

Care Center.

3/8" 3/8"

1

2

4D

4E

4F

4G

Additional Boundary Wire

Extra direct burial Boundary Wire can be purchased in 500 foot spools 

at the store where you purchased the kit or through the Customer 

Care Center.
Note: When adding Boundary Wire, it must act as a continuous loop.
The table at right indicates the approximate length of Boundary Wire 

needed for a square, Single Loop layout. Length will vary due to the 

amount of twisted wire and layout used.

Acres

Feet of Wire Needed

1/4

415

1/3

480

1/2

590

1

835

2

1180

5

1870

10

2800

25

4500

Summary of Contents for ultrasmart in-ground fence PIG00-13619

Page 1: ...ultrasmart in ground fence operating and training guide Model Number PIG00 13619 Please read this entire guide before beginning...

Page 2: ...hers If you are not sure that this product is right for your dog please talk to your veterinarian or a certified trainer Underground cables can carry high voltage Have all underground cables marked be...

Page 3: ...is may lead to a rash or infection The Receiver Collar should not be on your dog when the system is tested Your pet may receive an unintended correction The Boundary Width of the system must be tested...

Page 4: ...5 How the System Works 6 Key Definitions 6 Operating Guide 7 Install the Fence Transmitter 7 Charge the Receiver Collar 7 Lay Out the System 8 Sample Layouts 8 Position the Boundary Wire 9 Prepare the...

Page 5: ...E REA D THIS ENT IRE GUI DE BEF ORE BEG INN ING Other Items You May Need Additional wire and flags Part PRFA 500 Tape measure Small Phillips screwdriver Drill Shovel or lawn edger Pliers Wire strippin...

Page 6: ...in the Static Correction Zone Surge Protector Installed with the Fence Transmitter to protect it from lightning strikes and power surges Receiver Indicator Light Reflects the battery status and corre...

Page 7: ...he Receiver Collar The Receiver Collar Charger is designed to plug into a standard AC wall outlet and act as a charging stand for the Receiver Collar Choose a location close to a door that you and you...

Page 8: ...the Warning and Static Correction Zones to approximately 16 24 feet 8 12 feet on each side of the wire The Receiver Collar can be activated inside the house if the Boundary Wire runs along the outside...

Page 9: ...g fence It reduces the amount of wire which will need to be buried Run the wire from the Fence Transmitter to A A to B B to C C to D D to E E to F make a U turn and follow your path all the way back t...

Page 10: ...Make sure the copper Boundary Wire is not TWISTED WIRES BOUNDARY WIRE WATERPROOF SPLICE CORRECT INCORRECT 4C corroded If the Boundary Wire is corroded cut it back to expose clean copper wire Insert t...

Page 11: ...A Setting will alert after 60 days and the B setting will alert after 30 days To set the reminder turn the switch to the OFF position then move to either the A or B setting After the 30 or 60 days has...

Page 12: ...ong outlet converter Doing so will make the Surge Protector ineffective against surges or spikes 1 Turn the power OFF to the outlet that the Surge Protector and Fence Transmitter will be plugged into...

Page 13: ...icating a properly installed boundary loop If this does not happen refer to the Transmitter Status Indications label underneath the transmitter lid 6C or see the Troubleshooting section in this guide...

Page 14: ...l contact Customer Care Center Flashing Yellow every 1 second No Tone Unit is in PerfectFit mode for 90 sec after turning on Flashing Green every 1 second Chime 5 consecutive chimes for confirmed fit...

Page 15: ...ning tone you have identified the Field Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifying the F...

Page 16: ...y Wire on top of the fence and return it on the bottom of the fence to get the five foot separation needed Chain Link Fence 9A Weave Boundary Wire through the links or use plastic quick ties Wooden Sp...

Page 17: ...mmonly known as bed sores Avoid leaving the collar on the dog for more than 12 hours per day When possible reposition the collar on the pet s neck every 1 to 2 hours Check the fit to prevent excessive...

Page 18: ...ar 5 The Receiver Collar should fit snugly yet loose enough to allow one finger to fit between a Contact Point and your pet s neck 11F Allow your pet to wear the collar for several minutes then rechec...

Page 19: ...n on a positive note with lots of praise and play Remove the Receiver Collar after each training session Be sure to contain your pet by another means during the training period e g pen tie out leash e...

Page 20: ...eness Introduction to Static Correction Perform three sessions per day each lasting 10 15 minutes Goal To train your pet to stay in the Pet Area and respect the boundary Setup Set the Static Correctio...

Page 21: ...pet anytime he comes back into the Pet Area with or without help 6 Repeat this process with other distractions Use other family members during this process 7 If your pet does not respond to the Stati...

Page 22: ...home and can teach your pet to stay off of furniture away from trash or out of certain rooms The small battery operated Indoor Barrier fits discreetly inside your home and protects a circular area up...

Page 23: ...ol knob clockwise to increase the distance from the Boundary Wire that the Receiver Collar activates You can also adjust the Field Size Switch to another setting If using a Double Loop make sure Bound...

Page 24: ...and Receiver collar setting before beginning the System Test Follow the steps below to perform the system test 1 Remove the Receiver Collar from your dog and make sure it is fully charged 2 Turn the...

Page 25: ...imple test to determine the cause of a Boundary Wire Broken or Disconnected alarm indication You will need a short 15 foot piece of Boundary Wire with 3 8 inch of insulation stripped from both ends To...

Page 26: ...Wire to either side of your Boundary Wire where you cut it in half 7 Plug in the Fence Transmitter and check the Status Indicator Light If the Status Indicator Light glows solid green you can assume...

Page 27: ...hich the receiver is connected Contact the Customer Care Center This device complies with Industry Canada Rules This device complies with part 15 of the FCC Rules Operation is subject to the following...

Page 28: ...677 www petsafe net 400 1427 1 Covered by US Patents 6 184 790 6 327 999 6 459 378 6 807 720 7 046 152 7 068 174 7 117 822 7 204 204 7 278 376 7 345 588 7 394 390 7 404 379 7 426 906 7 495 570 7 574 9...

Reviews: