4. To splice wires:
a. Strip approximately 3/8 inch of insulation off the ends of the wires to be spliced.
b. Insert the stripped ends into a wire connector and twist the wire connector around the wires. Make sure there is no copper exposed
beyond the end of the wire connector, and that the wire connector is secure on the wire splice.
c. Tie a knot 3 to 4 inches from the wire connector.
d. Open the lid of the gel-filled capsule and insert the wire connector as deeply as possible into the waterproof gel inside the capsule.
e. Snap the lid of the capsule shut.
Your system comes with two gel-filled splice capsules to ensure that your splices are waterproof. We recommend using these capsules
for all splices in your boundary to ensure reliable fence operation over time. Additional splice capsules are available for purchase at
www.petsafe.com or by contacting our Customer Care team.