Petastor AH-825FHS Hardware Installation Manual Download Page 17

Chapter 1. Introduction   

 

 

11 

AN-816STS/D     SAS-SAS/SATA RAID SUBSYSTEM 

16   17   18          1                                14    2  15  19    20   21

22      23               7 10     

11     13             24        25

3      4  

12        

 

 

AN-816FQS/D     FC-SAS/SATA RAID SUBSYSTEM 

16   17   18          1                                14    2  15  19    20   21

22      23               7 10     

11     13             24        25

3  4  5   6    12        

 

 

AN-816FHS/D     FC-SAS/SATA RAID SUBSYSTEM 

AN-816iGS/D      10Gb iSCSI-SAS/SATA RAID SUBSYSTEM 

 

16   17   18          1                                14    2  15  19    20   21

22      23               7 10               11     13             24        25

5   6      12        

 

Summary of Contents for AH-825FHS

Page 1: ...Alnico Gen 2 Series RAID Subsystems AN812 AN816 AN824 AH 825 Hardware Installation Guide Version 1 0 Sep 30 2015...

Page 2: ...tion either express or implied and provide it as it This includes but is not limited to any implied warranties of merchantability and fitness for a particular purpose The information in this document...

Page 3: ...allation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the int...

Page 4: ...roubleshooting and future upgrades For the detail about how to configure your subsystem please refer to the Software Operation manual S S Sy y ym m mb b bo o ol l ls s s i i in n n T T Te e ex x xt t...

Page 5: ...EED 19 ESD PRECAUTION 19 INSTALLING HARD DISKS 20 INSTALL THE ALNICO RAID SUBSYSTEM IN A RACK 22 SYSTEM CONNECTION 24 CONNECTION TO ALNICO GEN 2 RAID SUBSYSTEM WITH SAS JBODS 25 TURNING ON FOR THE FIR...

Page 6: ...Hardware Installation Guide vi APPENDIX C SPECIFICATIONS 40 SPECIFICATIONS 40...

Page 7: ...k k ke e ey y y f f fe e ea a at t tu u ur r re e es s s a a an n nd d d s s su u up p pp p pl lli iie e ed d d a a ac c cc c ce e es s ss s so o or r ri iie e es s s M M Mo o od d de e el l l V V Va...

Page 8: ...rage subsystem Target usage ranges are set from small business to departmental and corporate server needs The RAID systems is designed for easy integration smooth data expansion and server migration T...

Page 9: ...background initialization Automatic drive insertion removal detection and rebuilding Understanding the Alnico RAID subsystem Front Panel Overview LCD Module Function keys ENT ESC Scroll up Scroll Down...

Page 10: ...Indicator LED never light up LED light up as Red Data Access Indicator Blink blue during host computer accessing the RAID subsystem LED never flickers For additional information on using the LCD pane...

Page 11: ...Chapter 1 Introduction 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 AN 812 1 2 3 4 5 6 7 8 9 10 11 12 AH 825 Drive Bay for AN Series 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24...

Page 12: ...ase Button Key Lock LED Indicator Red HDD Error LED Indicator Blue HDD Power on Flash Accessing Lock Unlock Drive Bay for AH Series Lock Unlock Handle Latch Key Lock LED Indicator Blue HDD Power on Fl...

Page 13: ...r Panel Overview AN 824STS D SAS SAS SATA RAID SUBSYSTEM 16 17 18 1 3 4 12 14 2 15 19 20 21 22 23 24 25 26 27 7 10 11 13 AN 824FQS D FC SAS SATA RAID SUBSYSTEM 16 17 18 1 3 4 5 6 12 14 2 15 19 20 21 2...

Page 14: ...7 18 1 5 6 12 14 2 15 19 20 21 22 23 24 25 26 27 7 10 11 13 1 Controller Box 1 2 Controller Box 2 AN 824STS D 3 SAS CH 1 LED Indicator 4 SAS CH 0 LED Indicator LED Colors Indicate SAS Green Link Blue...

Page 15: ...Gbps Link 8 Gbps Link 4 Gbps Link Blue Blink Access AN 824iGS D 5 iSCSI_CH_1 LED Indicator 6 iSCSI_CH_0 LED Indicator LED Colors Indicate iSCSI Green Amber 10 Gbps Link 1 Gbps Link Blue Blink Access...

Page 16: ...e Option 15 Power Switch 16 FAN failure indicator Rear Front 17 FAN Module 1 18 FAN Module 1 latch 19 FAN failure indicator Rear Front 20 FAN Module 2 21 FAN Module 2 latch 22 AC inlet 1 Latch 23 Powe...

Page 17: ...19 20 21 22 23 7 10 11 13 24 25 3 4 12 AN 816FQS D FC SAS SATA RAID SUBSYSTEM 16 17 18 1 14 2 15 19 20 21 22 23 7 10 11 13 24 25 3 4 5 6 12 AN 816FHS D FC SAS SATA RAID SUBSYSTEM AN 816iGS D 10Gb iSC...

Page 18: ...AN 816FQS D 3 FC_CH_3 LED Indicator 4 FC_CH_2 LED Indicator 5 FC_CH_1 LED Indicator 6 FC_CH_0 LED Indicator LED Colors Indicate FC Green Amber Green Amber Blink 16 Gbps Link 8 Gbps Link 4 Gbps Link Bl...

Page 19: ...Status Green Blink Raid Controller OK Fault Red Raid Controller Fault 8 Reserved 9 Reserved 10 SAS Expand Port 0 LED Indicator LED Colors Indicate SAS Green Link Blue Blink Access 11 Console 12 Termin...

Page 20: ...7 3 4 20 21 15 18 19 22 23 7 10 11 12 13 14 1 2 AN 812FQS D FC SAS SATA RAID SUBSYSTEM AH 825FQS D FC SAS SATA RAID SUBSYSTEM 16 17 3 4 5 6 20 21 15 18 19 22 23 7 10 11 12 13 14 1 2 AN 812FHS D FC SAS...

Page 21: ...ndicator LED Colors Indicate SAS Green Link Blue Blink Access AN 812FQS D 3 FC_CH_3 LED Indicator AH 825FQS D 4 FC_CH_2 LED Indicator 5 FC_CH_1 LED Indicator 6 FC_CH_0 LED Indicator LED Colors Indicat...

Page 22: ...Amber 10 Gbps Link 1 Gbps Link Blue Blink Access 7 Raid Controller Status LED Fault LED Indicator LED Colors Indicate Status Green Blink Raid Controller OK Fault Red Raid Controller Fault 8 Reserved 9...

Page 23: ...Chapter 1 Introduction 17 18 FAN failure indicator Rear Front 19 FAN Module 2 20 AC inlet 1 Latch 21 Power Module 1 22 AC inlet 2 Latch 23 Power Module 2...

Page 24: ...s st t tr r ru u uc c ct t ti iio o on n ns s s o o on n n h h ho o ow w w t t to o o c c co o on n nn n ne e ec c ct t t A A Al lln n ni iic c co o o R R RA A AI I ID D D U U Un n np p pa a ac c ck k...

Page 25: ...A in the Host computer and Alnico RAID Alnico RAID doesn t include the Fibre cable with the standard shipping W W Wh h ha a at t t e e el l ls s se e e y y yo o ou u u n n ne e ee e ed d d Hard disk d...

Page 26: ...all 4 screws to mount HDD in the bay and make sure the HDD is properly tightened Loading 3 5 Hard Disk to the drive bay for AN Series 1 Put 3 5 HDD into the bay 2 Fasten all 4 screws to mount HDD in t...

Page 27: ...use any size drive however the smallest drive will determine the size of the array 1 Only use the screws offered with Alnico Gen 2 RAID subsystem Longer screws might cause the drive damage 2 All the d...

Page 28: ...tem is designed for installation into a industry standard 19 inch rackmount cabinet Following the use of this section for installing the Alnico subsystem into a Rack Install the Slide Rails 1 Combine...

Page 29: ...k 1 Lift the subsystem enclosure and slide it slowly and gently along the slide rail into the rack as Figure 2 Figure 2 2 Fasten two M5 screws through the chassis ears in the front side of the chassis...

Page 30: ...ator Debug port to check and monitoring all of status of RAID subsystem Fibre cable MiniSAS HD Cable Primary FC AL SAS Secondly FC AL SAS FC AL SAS HBA of Host computer Host interface between RAID and...

Page 31: ...s s st t te e em m m w w wi i it t th h h S S SA A AS S S J J JB B BO O OD D Ds s s There are many topologies of SAS JBOD with Alnico Gen 2 RAID subsystems Ways to implement are as below One SAS Raid...

Page 32: ...Mini SAS Cable 1 Alnico Gen 2 RAID subsystem do not require the installation of different drivers for use with different operating systems Alnico Gen 2 RAID is independent and transparent to the host...

Page 33: ...re one or more RAID arrays You have the following options 1 Turn to Chapter 3 of Software Operation Manual to perform a quick setup of a single RAID array using the control panel 2 Turn to Chapter 6 o...

Page 34: ...ror message or if Alnico RAID s Internet manager indicates a fault determine the reason for this alert immediately Examine the component LEDs to see if any indicates a fault then replace it as soon as...

Page 35: ...g g gr r ra a ad d di i in n ng g g D D DI I IM M MM M M Alnico RAID AN 8 AH 8 series are normally supplied with 2Gb cache memory installed There s no set formula to determine how much cache memory to...

Page 36: ...the latches lock it into place 1 Before starting any kind of hardware installation please ensure that all power switches have been turned off and all power cords disconnected to prevent personal injur...

Page 37: ...he figure below Removing the Fan Module from Alnico 16bays and 24bays subsystems Remove the Fan modules by slide the release button left and pull the module out of system push Pull out Replace the Fan...

Page 38: ...e e t t th h he e e P P Po o ow w we e er r r M M Mo o od d du u ul l le e e This section provides instructions for the removal and installation of the Power Module indicated in the figure below Remov...

Page 39: ...o or rs s Ethernet RJ 45 Connector Pin Signal Name 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC Fibre SFP Pin Signal Name 1 VEFT 2 TFAULT 3 TDIS 4 MOD_DEF 2 5 MOD_DEF 1 6 MOD_DEF 0 7 Rate Select 8 LOS 9 VE...

Page 40: ...Hardware Installation Guide 34 RJ 11 miniSAS HD SFF 8644 Pin Signal Pin Signal 1 NC 6 NC 2 GND 3 RX 4 TX 5 CTS...

Page 41: ...x 1 A4 Rx 1 A5 Sideband 7 A1 Sideband 3 B1 Sideband 4 C1 Sideband 5 D1 Rx 2 B7 Rx 2 B8 Rx 3 A7 Rx 3 A8 Tx 0 D4 Tx 0 D5 Tx 1 C4 Tx 1 C5 Sideband 0 A2 Sideband 1 B2 Sideband 2 C2 Sideband 6 D2 Tx 2 D7 T...

Page 42: ...controller cache memory in the event of a power failure The Battery Backup Module monitors the write back cache on the external RAID controller and provides power to the cache memory if it contains da...

Page 43: ...ARC 8006 2 into controller s J7 AN 6 J8 AN 7 connector location is shown as bellowing Insert the 3pin Connector into Battery Board s ARC8006 2 JA2 connector Install the BBM and fasten 4 screws on BBM...

Page 44: ...kup capacity is defined as the maximum duration of a power failure for which data in the cache memory can be maintained by the battery The BBM s backup capacity varied with the memory chips that insta...

Page 45: ...ke sure of all the capacity of your battery cells allow the battery cell to be fully charged when installed for the first time The first time charge of battery cells takes about 24 hours to complete R...

Page 46: ...ve insertion removal detection and rebuilding Online capacity expansion and RAID level migration simultaneously Great than 2TB per volume set 64 bit LBA support RAID Levels 0 1 1E 3 5 6 50 60 JBOD Sup...

Page 47: ...ils SMTP Operating System Single controller OS independent and transparent Redundant controller MPIO Multipath I O driver required Power Supply Redundant by three 500W 80 Plus energy efficient power m...

Page 48: ...Offline RAID set Multiple RAID selection Automatic drive insertion removal detection and rebuilding Online capacity expansion and RAID level migration simultaneously Great than 2TB per volume set 64...

Page 49: ...mote to monitor events with no SNMP agent required System status indication through LCD LED and alarm buzzer All system events can be sent to multiple user alerts via e mails SMTP Operating System Sin...

Reviews: