Step
S
YSTEM
S
ET
-U
P AND
C
ONFIGURATION
If not already powered-up from previous step, apply power to C22 and allow it to
complete boot-up sequence.
Open a web browser on a network connected PC and enter the IP address of the C22
in the browser URL address bar.
NOTE:
Currently set IP address of C22 module is shown by the front panel display
The login screen as shown here should open.
If the login screen does not open, or you receive a communication error message,
open a command entry window from the Windows Start button and ping the default IP
address.
If the ping is successful, try using a different web browser.
If the ping is not successful, consult your facility IT administrator for possible network
conflicts.
6
Step
M
ODIFY
C22 N
ETWORK
C
OMMUNICATION
P
ARAMETERS
If you do not need to modify the C22 network communication parameters, continue to
Step 7.
Open the C22 webcenter control application to the login screen. Refer to Step 5.
Login to webcenter using the default administrator account with the following
credentials:
Username –
admin
Password –
a
Select the System button from the landing page as shown here.
5
Step
E
STABLISH
C
ONNECTION TO
C22 W
EBCENTER
C
ONTROL
A
PPLICATION
(C
ONT
.)
Part No. 81-9059-0732-0 Rev. A
Quick-Start Guide
C22
For further information, refer to PESA Xstream C22 User Guide
C
ONTINUED ON
N
EXT
P
AGE
HDMI In
– Native HDMI input port. May attach a DVI input signal with an adapter
cable. Input signal at this connector may be selected as a source signal for either
processing channel.
HDMI Out
– HDMI output port. May attach a DVI input signal with an adapter
cable. Output signal at this connector may be selected through software as the
local output of processing channel 1 or 2.
Reference
– Accepts an input of analog video sync reference from an external
source, such as tri-level sync.
I/O 1 and 2
– These BNC connectors provide a bi-directional video interface for
SMPTE SDI video with embedded audio. Through control software, either BNC
may be configured as a video input port or output port for its respective
processing channel, 1 or 2. By default, each BNC is configured as an input port.
SFP
– Dual channel mounting cage for installation of a variety of SFP input or
output modules. Both SFP channels may function as an input port or output port,
depending on the SFP module installed.
4
Step
C
ONNECT
V
IDEO
& A
UDIO
I/O
AND
N
ETWORK
C
ABLES TO
C22 (C
ONT
.)
PWR
ETHERNET AUDIO
OUT 1/2
IN 1/2*
IN 2*
USB
+12VDC
*See User Guide
4
Step
C
ONNECT
V
IDEO
& A
UDIO
I/O
AND
N
ETWORK
C
ABLES TO
C22 (C
ONT
.)
3.5mm Male to
Male Cable
Direct Connection to
Unbalanced PC
Audio Output
IN 2 Not
Used in This
Application
E
XAMPLE
- U
NBALANCED
A
UDIO FROM
PC
When connecting unbalanced
input audio sources to C22,
such as the output from a
computer, both channels are
attached through the
IN 1/2
3.5mm connector.
Pinouts for C22 input and a PC
sound card output are pin-for-
pin compatible.
IN 2
connector is not used
when attaching unbalanced
inputs.
E
XAMPLE
- B
ALANCED
A
UDIO FROM
E
XTERNAL
M
ICROPHONES
Tip
Ring
Sleeve
Chnl 1 (L) +
Chnl 2 (R) +
Common
Ground -
Chnl 1 (L) +
Chnl 1 (L) -
Channel 1
Shield
IN 1/2
Unbalanced
Inputs
IN 1/2
Balanced
Inputs
IN 2
Balanced
Inputs
Chnl 2 (R) +
Chnl 2 (R) -
Channel 2
Shield
*Analog Audio Input & Output Pinouts
NOTES
Connector
IN 2
Not Used when Attaching Unbalanced Inputs
Analog Audio Outputs are Unbalanced Only
Phantom Power Available Only with Balanced Inputs
Chnl 1 (L) +
Chnl 2 (R) +
Common
Ground -
OUT 1/2
Unbalanced
Outputs
Connector
When connecting balanced input
audio sources to C22, such as from a
microphone with XLR connector,
each channel is attached through one
of the 3.5mm connectors. See pinout
table at bottom of this column.
Inputs may be line level or
microphone level. C22 auto-detects
input level of source.
Phantom power for condenser
microphones may be switched to
both inputs through webcenter
configuration page.
PWR
ETHERNET AUDIO
OUT 1/2
IN 1/2*
IN 2*
USB
+12VDC
*See User Guide
C22 factory default network communication parameters are:
IP Address
192.168.1.100
Subnet Mask
255.255.255.0
Gateway
192.168.1.1
Verify that the factory default parameters are compatible with your facility network,
and that the default IP address will not cause a network conflict before applying
power to C22.
Verify that the C22 Ethernet port is connected to the facility network.
Once you have established network communication with C22, you may change
the operating network communication parameters of the device for network
compatibility through the webcenter control application. Refer to Step 6.
If factory default parameters are not compatible, and you can not access the
webcenter over the facility network, it will be necessary to modify the network
parameters with the C22 and a PC in a direct Ethernet connection while not
connected to the LAN as follows:
- Log the PC off of the network and remove the Ethernet cable connection to
the PC.
- Open the Windows Control Panel and configure the PC with a unique IP
address and compatible Ethernet parameter settings for network
communication with the C22 using its factory default network settings.
- Use a Cat5 network cable to directly connect C22 rear panel Ethernet
connector to the PC Ethernet connector. A crossover Cat5 cable is not
required for this connection.
- Apply power to C22 and allow it to complete boot-up sequence.
- Perform the remaining steps presented here and in Step 8 to change the
network parameters of C22 as necessary for LAN compatibility using the
webcenter control application.
- Remove power to the C22.
- Reconfigure the PC for communication on the facility LAN.
- Reconnect the PC and C22 to the facility Ethernet.
- Apply power to the C22 and allow it to complete boot-up sequence.
- You should now be able to connect to the C22 webcenter over the facility
network.
5
Step
E
STABLISH
C
ONNECTION TO
C22
W
EBCENTER
C
ONTROL
A