PESA Smart 32 User Manual Download Page 15

Smart 32 Remote Control Panel User Guide 

Publication 81-9059-0727-0, Rev. A 

April 2014 

Proprietary Information of

 

PESA

 

 

4-3 

 

 

Real-Time Status Display Area 

-

 

Destination – Indicates the router destination group currently controlled by the panel. Unless 
a different destination is selected using a pushbutton key, the active destination of the panel is 
the default destination entered during panel configuration through Cattrax. 

-

 

Source – Indicates the source group currently switched to the destination controlled by the 
panel on the indicated switching level. When a pound symbol (#) appears beside the source 
name, it indicates a breakaway condition, meaning that the indicated source is not routed to 
the destination on all switching levels.  

Level – Indicates the highest ranking switching level on which the panel is currently showing 
status. Refer to Paragraph 4.2.  

-

 

Active Page – Indicates the currently selected page of pushbutton key assignments. 

4.4

 

H

OW 

F

UNCTIONS ARE 

A

SSIGNED TO 

C

ONFIGURABLE 

P

ANEL 

K

EYS

 

PESA’s Smart 32 remote control panel provides 32 front panel keys, any of which may be assigned to 
any key function. It also supports a pagination system that allows you to create up to 16 distinct pages of 
all 32 front panel keys, for a total of 512 assignable panel keys.  

Key function for all panel keys is assigned when the panel is configured into the system controller 
through creation of a panel key list. It is not possible to assign or edit key function directly from the 
panel. The panel key list configuration page from Cattrax is introduced here only to give the panel 
operator a better understanding of how key functions and pages are assigned. For information on 
configuring a panel key list and downloading it to the system controller, refer to PERC3000 System 
Controller Installation and Operation User Guide.  

Figure 4-1 is an illustration of the Cattrax Panel Key List configuration page. Notice there are two 
spreadsheet type grids on the lower portion of the page. 

 

 

Figure 4-1 Smart 32 Panel Key List Page  

Summary of Contents for Smart 32

Page 1: ...USER GUIDE SMART 32 PROGRAMMABLE NETWORK BASED REMOTE CONTROL PANEL Publication 81 9059 0727 0 Rev A www PESA com April 2014 Phone 256 726 9200...

Page 2: ...y Circle Suite 210 Huntsville AL 35806 USA www PESA com MAIN OFFICE Tel 256 726 9200 Fax 256 726 9271 CUSTOMER SERVICE DEPARTMENT Tel 256 726 9222 24 7 Toll Free 800 323 7372 Fax 256 726 9268 Email se...

Page 3: ...F INTRODUCTION TO SMART 32 PANEL OPERATION 4 1 4 2 SWITCHING LEVEL IDENTIFICATION AND RANKING 4 2 4 3 FRONT PANEL USER INTERFACE 4 2 4 3 1 Pushbutton Keys 4 2 4 3 2 Status Screen Display 4 2 4 4 HOW F...

Page 4: ...FIGURES FIGURE 2 1 SMART 32 CONTROL PANEL FRONT VIEW 2 1 FIGURE 2 2 SMART 32 STATUS DISPLAY SCREEN 2 2 FIGURE 2 3 TYPICAL PERC3000 SYSTEM CONTROLLER INSTALLATION 2 4 FIGURE 3 1 SMART 32 CONTROL PANEL...

Page 5: ...re or sequence outlined in this document 1 2 CAUTIONS AND NOTES Cautions and Notes are addendum statements used in this guide that supply necessary information pertaining to the text or topic they add...

Page 6: ...tus readout and other panel parameter display functions An illustration of the Smart 32 panel is shown by Figure 2 1 Figure 2 1 Smart 32 Control Panel Front View Smart 32 panels communicate with the P...

Page 7: ...assigned using a system wide default color scheme to instantly identify each key by function type on any Smart 32 or Touch 72 panel on the network The factory default color scheme may be modified on a...

Page 8: ...ements and allows efficient communications between all system components Many PESA router products such as the Jaguar Ocelot and Cougar and some third party protocol converter devices communicate with...

Page 9: ...Controller Installation 2 5 SPECIFICATIONS GENERAL Mounting 1RU Push buttons 32 Multi color Illuminated with Programmable Text and Graphics NETWORK Communications Port Ethernet POWER Voltage Requirem...

Page 10: ...of the router system it must be configured for integration with the system and added to the controller configuration file loaded in the system controller Configuration and set up is done using Cattrax...

Page 11: ...Note that he Smart 32 will not allow a zero to be configured for the IP Netmask or Gateway If at any time you wish to change the IP address of a Smart 32 panel change the address data through the Catt...

Page 12: ...e with Chapter 5 of the PERC3000 User Guide Rev D A Smart 32 panel will not communicate with system controller or operate the router until it is added to the controller configuration If you are changi...

Page 13: ...e Panels Configuration page Once a list is created it may be used with multiple panels Panel Key Lists Smart 32 panels provide 16 pages of 32 pushbutton keys used for command and data entry Individual...

Page 14: ...e Level for which the panel is currently showing status the actual switching level for which source and destination status is shown will be the level defined as the Status Level for the panel during p...

Page 15: ...pushbutton key assignments 4 4 HOW FUNCTIONS ARE ASSIGNED TO CONFIGURABLE PANEL KEYS PESA s Smart 32 remote control panel provides 32 front panel keys any of which may be assigned to any key function...

Page 16: ...ing to the panel key and selecting the resource or function it is assigned from the tabbed pages of the right grid Referring to Figure 4 1 the key assignments of the panel keys on page 1 are displayed...

Page 17: ...igurable pages shown by Figure 4 3 there is an additional page in the Available Page List labeled Panel Info that may be assigned to any panel key When this page function is assigned and the key selec...

Page 18: ...the system controller EXIT Returns the Smart 32 panel to the previous key assignment page The following control keys for adjusting display and pushbutton illumination refer to Paragraph 4 14 are also...

Page 19: ...panel key may be assigned to any one of the following router control functions Lock toggles between lock protect unlock Page Key Cyan A pushbutton key may be assigned to select one of the panel key pa...

Page 20: ...For example refer to the grid in Figure 4 5 and look at the row for Source 1 The Panel Name is FS 1 and is the label entered during source group configuration for display on remote control panels By...

Page 21: ...text label Cattrax supports a library of common graphic images in a pull down list as shown here using the Sources system resource tab for the example Available graphic images vary depending on the t...

Page 22: ...ront panel pushbutton keys that quickly identify the system resource type assigned to each key by the background color regardless of which panel you are using If desired you may select the background...

Page 23: ...he use of switching levels components sources source groups and destinations destination groups created and assigned through the controller configuration file Loosely defined a switching level is a gr...

Page 24: ...ideo router at output 1 and the left and right audio inputs to the DRS audio router at audio outputs 1 and 2 respectively Through controller configuration we can add a destination group entry that cre...

Page 25: ...itching level AUDL and input 4 as the signal source for switching level AUDR Using a breakaway switch we can select NET1 as the source for switching level 1 VID and REC1 as the source for switching le...

Page 26: ...l switching levels are selected from panel keys assigned to select a level the Level line of the status screen displays the level name of the highest ranking level of all the selected levels and the S...

Page 27: ...group are routed to destination outputs on only the switching levels defined for the breakaway switch When a source is selected the pushbutton lights and the switch immediately occurs 4 13 APPLYING D...

Page 28: ...wn arrow keys for the desired backlight intensity as shown below A numerical readout of the relative backlight intensity value is shown in the status display Press the EXIT button to return to the pre...

Page 29: ...consult your warranty documents and PESA s Customer Service Department Unauthorized repairs may void your warranty PC boards in this equipment contain Surface Mount Technology SMT components Special...

Page 30: ......

Reviews: