Perun V2 Hybrid User And Installation Manual Download Page 6

5.

 

Features and programming 

Supplementary  video  manual  is  available  here: 

https://www.youtube.com/watch?v=2o4eWEYyw7c

 

To enter the programming mode: 

F

or  “SEMI”

 

 

keep  the  selector  on  “SEMI”  for  a 

couple  of  seconds,  then  go  to  “AUTO”  and  back, 

twice.  (

“SEMI”  →

 

“AUTO”  →

 

“SEMI”  →

 

“AUTO”  →

 

“SEMI”

Successful  entry  into  the  programming  mode  for 

“SEMI”

 will be confirmed by 

one sound signal and a  

blue LED light. 
Fo

r  “

AUTO

 

 

keep  the  selector  on  “AUTO”  for  a 

couple of seconds, then go to “SEMI” and back, twice

(

“AUTO” →

 

“SEMI” →

 

“AUTO” →

 

“SEMI” →

 

“AUTO”

Successful  entry  into  the  programming  mode  for 

“AUTO”

 will be confirmed by 

three sound signals and 

red LED light.

 

Switching the selector 

between “AUTO” and “SEMI” 

and back allows to move between the modes. Pulling 
the trigger allows to enable, disable, or set levels for 
the modes.

 

Full feature description 

All the settings are set independently for “SEMI” and “AUTO” 

selector positions, except for Li-Po 

alarm and Master reset, which work for both selector positions. 

Function and 

LED color

 

Description

 

Firing mode

 

 

Green 

Choose firing modes for each selector position: safe, semi, 1-5 shot burst and auto. 
 
No sound signal, steady green light 

 safe 

1 short single signal and blink 

 semi 

2-5 short signals and blinks 

 2-5 round burst 

1 long signal and blink 

 auto 

AB

 

 

Blue 

Active brake (AB) stops the motor after the shot, preventing the spring from remaining 
in a compressed state and eliminates double shots on semi in replicas with high rate of 

fire (“overspin”). 

5 levels of braking strength are available 

 from 1 (weakest braking) 

to 5 (the strongest). Braking can be also completely disabled. It is advised not to use 
braking or use it on the lowest level, if stronger braking is not necessary, as it negatively 
impacts the service life of motor brushes and causes increased heating. 

Tip: 

Switch to semi, fire a single shot, and hold the trigger after the shot. This will cause 

a second single shot with strongest AB setting to be fired after 3 seconds, making sure 
the spring remains uncompressed. It is advised to do that when you finish shooting. 
 

Attention!

  While  precocking  is  on,  the  AB  setting  becomes  irrelevant.  However,  any 

programmed AB setting will be stored in memory and will become effective as soon as 
precocking is disabled.

 

 
No sound signal while LED glows blue means, that the active brake is disabled. 1 to 5 
signals indicate braking levels from 1 (the weakest) to 5 (the strongest). 

Summary of Contents for V2 Hybrid

Page 1: ...Adaptive trigger control allows switching from a very short trigger travel to a long one even in the field with almost any trigger including stock ones Reading this manual will help you fully exploit...

Page 2: ...oxes see page 13 KWA ERG replicas are not compatible These are gearboxes that we tested for compatibility during the design process Please be advised that despite our best efforts to provide reliable...

Page 3: ...Do not use excessive force though 3 Install the plastic magnet holder on the trigger as shown on the photo to the right When screwing the two halves of the holder together use only little force not to...

Page 4: ...rking make sure that the magnet together with its plastic holder is on the trigger and it is placed correctly The correct polarization of the magnet which end of the magnet is pointing at the board is...

Page 5: ...e trigger pull necessary to fire a shot longer than it would have been when left in the standard forward position When in normal semiautomatic mode the Perun Hybrid uses a progressive trigger activati...

Page 6: ...nd auto No sound signal steady green light safe 1 short single signal and blink semi 2 5 short signals and blinks 2 5 round burst 1 long signal and blink auto AB Blue Active brake AB stops the motor a...

Page 7: ...When the two stage trigger is enabled the binary trigger is automatically disabled No sound signal while LED blinks purple and teal alternately means that the binary trigger is disabled 1 signal indi...

Page 8: ...further used and must be recharged Unit automatically detects number of cells in the battery and determines safe voltage range The need for battery replacement is signaled by short sound signals every...

Page 9: ...ted by parts combination which draws too much current e g high speed motor and gears The unit will start functioning normally after the battery is reconnected unless there still is a short circuit tha...

Page 10: ...most preferably with a T deans socket made by different manufacturer Battery and or the motor heat up very much The battery has too low capacity mAh and or C parameter Use a battery with higher capaci...

Page 11: ...rtup this can activate the error Make sure the trigger can move freely and completely unobstructed Use stronger trigger spring When RoF reduction is enabled electronic fuse activates or the replica ju...

Page 12: ...nge at this moment Selector switched to AUTO Red This should happen after the selector is switched to AUTO Selector switched to SEMI Blue This should happen after the selector is switched to SEMI Sele...

Page 13: ...no components and paths are visible in the area you want to modify Krytac Remove the small knob on the right gearbox half near the contacts Make room for the sector gear LED leg by making a small dent...

Reviews: