Instruction manual for use and maintenance
for WM1L/S WM1L/S-M WM1L/E Single
head machines
File: 1927.doc - 25/01/02 11:55
30
- The electronic controller starts diminishing the entered seconds as the end-of-fusion sensor is
activated. At the end of the count the welding plate lifts and the pieces are united.
- We recommend to enter a value between 20 and 25 Seconds.
6.4 Cooling Timer
- To enter the value of the cooling timer act on key:
The display shows:
COOLING TIMER
30.0
<ESC>
- The value indicated on the left is the one entered by the operator (in seconds).
- Use the keyboard to enter the desired value and press ESC to exit and confirm the entered
value.
- The electronic controller starts the count-down of the entered seconds as the two pieces are
united, at the end of the count the machine releases the pieces.
- We recommend to enter a value between 25 and 30 Seconds.
ATTENTION
To verify the correctness of the entered values and of the right combination among
them, periodically check the welded angles strength against breaks.
6.5 Mechanical parameters for welding
The machines are supplied with the following standard regulation of the mechanical welding
parameters:
WM1L/S – WM1L/S-M
- Reduction of the welded profile length 2.5 mm (for each welded side)
- Limitation of welding seal 2 mm (upon request 1 mm – 0.2 mm)
WM1L/E
- Reduction of the welded profile length 2.5 mm. (for each welded side)
- Limitation of welding seal 2 mm (upon request 1 mm)
Should the customer have requirements that differ from our standard, he may ask, when
ordering or after the machine supply, to modify the above mentioned parameters.
Summary of Contents for WM1L/E
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 59: ...5 3 1 2 4 3 5 4 2 1...