Perrin & Rowe EDWARDIAN U.KIT1323 Installation Instructions Manual Download Page 10

INSTALLATION INSTRUCTIONS

Electrical Requirements 

A standard 120v electrical outlet is required under the sink. If possible, use a separate circuit dedicated to your Hot 
Tank. It is recommended that a separate circuit serving only your electronic instant hot water appliance be provided 
or use an outlet that can be turned on/off by a switch. This electronic instant hot water appliance is equipped with a 
power supply cord with a power plug. To minimise possible shock hazard, the cord must be plugged into mating, 
ground-type outlet, grounded in accordance with all national and local codes and ordinances. If a socket outlet is not 
available, it is the responsibility and obligation of the customer to have a properly grounded outlet installed by a 
qualified electrician. 

Water Supply Requirements 

If local codes permit, the instant hot water Dispenser feed line should be connected to the hot and cold water supply 
line using an isolation valve or another means for providing the hot and cold water to the Dispenser. IMPORTANT: If 
local codes do not permit the use of isolation valves, special feed valves can be obtained from your local plumbing 
supply distributor. f the water is mixed with impurity, ironing chips, grains of sand, and so on, the pipes of the electron-
ic instant hot water appliance and Dispenser will be blocked and will void the guarantee. 

 

Environment requirement 

Don't install the electronic instant hot water appliance outdoors or in a location that may fall below 32F, otherwise the 
pipes and the Dispenser and tank will be frozen and there will be serious safety trouble, possible bodily-injury, acci-
dents and damaged caused and the guarantee will be void. It's forbidden to wash the electronic instant hot water 
appliance with water directly. The installation environment should be ventilated, with protection from the direct sun-
shine. When installing the electronic instant hot water appliance, provide approximately 10cm to 15cm (4 - 5 ½”) of air 
space on the sides of the unit for air circulation and approximately 2.5cm (1”) from the mounting wall. The environ-
ment humidity should be in the range of 10% to 60%. Be sure there is no dew. 

Instant Hot Water Dispenser Information 

Connecting a standard Dispenser may cause injury and will damage the electronic instant hot water appliance and void 
the guarantee. Due to high water temperature, and for safety reasons, the electronic instant hot water appliance is not 
under pressure.  

Instant Hot Water Appliance Temperature Adjustment  

For temperatures above 203F:- it has been set for optimum performance in most common and typical known installa-

tions. However there are factors which may influence the performance of the instant hot water appliance  such as 

incoming water temperature, atmospheric pressure and altitude.  Should you experience any discharge of water from 

the spout during heat up,  you can reduce the setting to compensate for this by 3F degrees at a time.  If in doubt please 

ask your dealer for further guidance.

 

 

 

 

INSTALLATION REQUIREMENTS 

Consult your local House of Rohl showroom for additional information and specifications. For complete warranty details and a list of showrooms, go to houseofrohl.com

houseofrohl.com

Summary of Contents for EDWARDIAN U.KIT1323

Page 1: ...ater for beverages and food preparation Unique Anti Scald lock innovative push mechanism with exclusive spring back valve Long lasting brass construction Swivel spout for ease of filling containers Or...

Page 2: ...TO MINIMISE RISK AND POTENTIAL INJURY TWO ACTION OPERATION SPRING BACK VALVE AND DELAYED DELIVERY BUT SHOULD BE OPERATED OR SUPERVISED BY A RESPONSIBLE ADULT PLEASE READ AND FULLY UNDERSTAND THE HEAT...

Page 3: ...er Feed the flexible connections through the 1 1 4 work surface hole ensuring the base seal is in place between tap and mounting surface Ensure the base ring and tap are orientated correctly Hot water...

Page 4: ...106 and heater tank U 1998 See separate filter guide and heater tank installation for further installation instructions Mount the filter housing in an accessible location using either screws in the br...

Page 5: ...ge the plated finish and void your warranty BEFORE USE Carefully check the installation for leaks If further building work is to be carried out in the vicinity cover the mixer tap to avoid damaging th...

Page 6: ...lease read these instructions fully before commencing the installation and operation of the Electronic Instant Hot Water Appliance Consult your local House of Rohl showroom for additional information...

Page 7: ...ld only be installed by a competent person if you feel for any reason unsure about the installation please contact a qualified plumber or electrician to install the appliance Make sure all electrical...

Page 8: ...hock Using an ungrounded connection or improper connection of the power sup ply to the product can result in a serious injury or death from electrical shock Electric Shock Do not remove the earthing t...

Page 9: ...re the front of the unit is visible and the front temperature dial can be easily reached Do not attempt to open modify or service this electronic instant hot water appliance Re pairs should be carried...

Page 10: ...ise the pipes and the Dispenser and tank will be frozen and there will be serious safety trouble possible bodily injury acci dents and damaged caused and the guarantee will be void It s forbidden to w...

Page 11: ...ic instant hot water appliance is not under pressure consequently there is a slight delay in water flow after the hot water springback Dispenser handle has been turned on This is normal and indicates...

Page 12: ...socket it must be tested for water tightness and no leaks Open all water valves to allow water to flow to the instant hot water Dispenser Turn the spring back instant hot water handle and hold to fill...

Page 13: ...s 208 F max 206 F 203 F 194 F 185 F 176 F 167 F To turn on the electronic instant hot water appliance touch the button and hold for 3 seconds until the display lights up Touch the button and press eac...

Page 14: ...ow the tank to cool for at least 1 hour Disconnect the inlet supply to the tank and remove the silicone hose out let pipe lift the unit to the sink turn upside down and drain all the water from the ta...

Page 15: ...he circuit breaker and fuse are working correctly Turn on the power and touch the on off button and then set the required temperature and confirm the heat up Water is too hot Water temperature setting...

Page 16: ...lume of water has been drawn off there may a slightly longer delay in the wa ter appearing from the instant hot water Dispenser spout Check length of silicon pipe No Water Flowing Water Valves have be...

Page 17: ...home com Guarantee Void Unless The Water Filter Is Replaced Every 6 Months Issue PRV114112017 Rohl Perrin Rowe are Registered trade marks Consult your local House of Rohl showroom for additional infor...

Page 18: ...dy to use it is vitally important that you follow the process below to ensure that all air is bled from the system P Pl la ac ce e a a j ju ug g u un nd de er r t th he e s sp po ou ut t a as s w wa a...

Page 19: ...th ho or ro ou ug gh hl ly y c ch he ec ck k t th he e u un ni it t f fo or r a an ny y w wa at te er r l le ea ak ks s b be ef fo or re e y yo ou u c co on nt ti in nu ue e 2 G3 8 BRAIDED HOSE FROM T...

Reviews: