7
If you require the voltage setting to be
altered, e.g. relocation to another area, city or
country, or extraordinarily high or low
voltages, contact your Perreaux dealer. This
modification must only be performed by
qualified service personnel.
Note: Always ensure the unit is disconnected
from the Mains/Line supply before any covers
are removed.
MAINS/LINE FUSE
The Perreaux 200P is equipped with a user
serviceable mains/line fuse. Above the
mains/line cord is the mains/line fuse holder.
In the unlikely event of fuse failure always
replace with the same type and value fuse.
Remember, fuses do not usually blow without
a reason. Any doubts about fuse failure
should be conveyed directly to your Perreaux
dealer.
The fuse ratings are:
100-125V 2SB SLOW BLOW 8A
Continuous
200-250V 2SB SLOW BLOW 6A
Continuous
Note: Always ensure your 200P is
disconnected from the Mains/Line supply
before attempting to change the Mains/Line
fuse.
RAIL FUSES
The Perreaux 200P has 4 internal fuses for
amplifier protection. In the unlikely event of
internal fuse failure consult your Perreaux
dealer. The internal fuses
are not user
serviceable
and only authorised personnel
may replace the internal fuses.
Fuse Rating -3AG Normal Acting 6 Amp
SERIAL NUMBER
All Perreaux units are allocated a unique
serial number which are recorded at the
factory against build details. If you should
require information about your unit, providing
the serial number will help achieve a prompt
reply.Keep a copy of all your serial numbers
in a safe place. The ability to identify and
prove ownership can be very useful.
SPECIFICATIONS
Tested at 120 / 220 / 230 / 240V ac
mains voltage after initial 10 minute warm
up period
POWER
OUTPUT
200 watts RMS per channel continuous
both channels driven into 8
Ω
from 20Hz
to 20kHz at no more than 0.02% THD
300 watts RMS into 4
Ω
FREQUENCY
RESPONSE
±
0.25dB from 20Hz to 20kHz
TOTAL HARMONIC DISTORTION
0.02% THD worst case prior to clipping
0.004% THD @ 1KHz
HUM,
NOISE
-95dB unweighted referenced to rated
output
INPUT
SENSITIVITY
Balanced 0.6V
RMS
Unbalanced 1.2V RMS
INPUT
IMPEDANCE
Balanced
3.3k
Ω
Unbalanced
22k
Ω
DYNAMIC
HEADROOM
1.9dB
CURRENT
OUTPUT
24 Amperes peak per channel
DRIVER
STAGE
Class
A
OUTPUT
STAGE
Class A / AB
DIMENSIONS (not including handles and
terminals)
HEIGHT x WIDTH x DEPTH
88mm x 482mm x 460mm
3.5" x 19.0" x 18.1"
NETT
WEIGHT
17.0kg
(37.5lb)