If you require the voltage setting to be 
altered, e.g. relocation to another area, city or 
country, or extraordinarily high or low 
voltages, contact your Perreaux dealer.  This 
modification must only be performed by 
qualified service personnel. 
 
Note: Always ensure the unit is disconnected 
from the Mains/Line supply before any covers 
are removed. 
 

MAINS/LINE FUSE

 

 
The Perreaux 200P is equipped with a user 
serviceable mains/line fuse.  Above the 
mains/line cord is the mains/line fuse holder.  
In the unlikely event of fuse failure always 
replace with the same type and value fuse.  
Remember, fuses do not usually blow without 
a reason.  Any doubts about fuse failure 
should be conveyed directly to your Perreaux 
dealer. 
 

The fuse ratings are: 

  100-125V 2SB SLOW BLOW 8A 
 Continuous 
  200-250V 2SB SLOW BLOW 6A 
 Continuous 
Note: Always ensure your 200P is 
disconnected from the Mains/Line supply 
before attempting to change the Mains/Line 
fuse. 

 
RAIL FUSES 

 

The Perreaux 200P has 4 internal fuses for 
amplifier protection. In the unlikely event of 
internal fuse failure consult your Perreaux 
dealer. The internal fuses 

are not user 

serviceable

 and only authorised personnel 

may replace the internal fuses. 

 
Fuse Rating -3AG Normal Acting 6 Amp 
 

SERIAL NUMBER

 

 
All Perreaux units are allocated a unique 
serial number which are recorded at the 
factory against build details. If you should 
require information about your unit, providing 
the serial number will help achieve a prompt 
reply.Keep a copy of all your serial numbers 
in a safe place.  The ability to identify and 
prove ownership can be very useful.

 

 
SPECIFICATIONS 
 
 

Tested at 120 / 220 / 230 / 240V ac 
mains voltage after initial 10 minute warm 
up period 

 

 

 POWER 

OUTPUT 

 

200 watts RMS per channel continuous 
both channels driven into 8

 from 20Hz 

to 20kHz at no more than 0.02% THD 

 
 

300 watts RMS into 4

 

 FREQUENCY 

RESPONSE 

 

±

 0.25dB from 20Hz to 20kHz 

 

 

TOTAL HARMONIC DISTORTION 

 

0.02% THD worst case prior to clipping 

 

0.004% THD @ 1KHz 

 

 HUM, 

NOISE

 

 

-95dB unweighted referenced to rated 
output 

 

 INPUT 

SENSITIVITY 

 

Balanced 0.6V 

RMS 

 

Unbalanced 1.2V RMS 

 

 INPUT 

IMPEDANCE 

 Balanced 

 

3.3k

 

 Unbalanced 

22k

 

 
 DYNAMIC 

HEADROOM 

 1.9dB 

 CURRENT 

OUTPUT

 

 

24 Amperes peak per channel 

 

 DRIVER 

STAGE

 

 Class 

 

 OUTPUT 

STAGE

 

 

Class A / AB 

 

DIMENSIONS (not including handles and 
terminals) 

 

 

HEIGHT  x  WIDTH  x  DEPTH

 

 

88mm x 482mm x 460mm 

 

3.5" x 19.0" x 18.1" 

 

 NETT 

WEIGHT 

 17.0kg 

(37.5lb) 

 

 

Summary of Contents for 200

Page 1: ...MODEL 200 200P DUAL CHANNEL POWER AMPLIFIER OWNERS MANUAL ...

Page 2: ...ality that you expect from us and we expect from ourselves Perreaux products are essentially hand crafted We maintain the human link throughout from design and construction through to the ultimate test your music your system your ears Because we too listen to our products we know that with your Perreaux you will discover many more of the musical secrets we strive to reveal Note All references to M...

Page 3: ...non caustic detergent DO NOT USE SOLVENTS 10 Non use Periods The mains power cord of the 200P should be unplugged from the mains line outlet when the unit is to be left unused for long periods of time 11 Object and Liquid Entry Care should be taken so that objects and or liquids do not accidentally fall inside the 200P 12 Damage Requiring Service The 200P should be serviced by qualified service pe...

Page 4: ...The red LED indicator behind the smoked panel on the front panel will illuminate when the power is turned on REAR PANEL 2 UNBALANCED INPUT SOCKETS These are high quality gold plated sockets which are highly conductive corrosion resistant and provide less potential for corrosion induced distortion Inputs are clearly marked Left and Right Care should be taken to maintain channel integrity Refer to s...

Page 5: ...n incorporates all the information in the various areas of this manual to assist installation When connecting the 200P to auxiliary equipment terminate the interconnect cables with a red plug for the right channel and white black or blue for the left channel Terminate speaker cables using red for positive and black white or blue for negative These are the most commonly accepted colour coding combi...

Page 6: ... indicated on the rear panel or owners manual Always ensure your 200P is disconnected from the mains line supply if changing the mains line fuse Do not drive the inputs with a voltage source greater than that which is required to drive the 200P to its maximum dynamic output Do not run the outputs in series or parallel Do not earth any positive terminal or connect the input to the output earth Do n...

Page 7: ...er The internal fuses are not user serviceable and only authorised personnel may replace the internal fuses Fuse Rating 3AG Normal Acting 6 Amp SERIAL NUMBER All Perreaux units are allocated a unique serial number which are recorded at the factory against build details If you should require information about your unit providing the serial number will help achieve a prompt reply Keep a copy of all ...