ROHO MOSAIC Cushion Operation Manual

Troubleshooting

For additional assistance, contact your equipment provider, distributor, or ROHO, Inc.

Not Holding Air

Inflate the cushion. Inspect the inflation valve and hose for damage. Confirm 
that the inflation valve is completely closed. Look for holes in the cushion. If 
very small holes or no holes are visible, follow the instructions in the Repair 
Kit provided with your product. For inflation valve or hose damage, or for large 
holes or leaks in the cushion, see the Limited Warranty supplement, or contact 
Customer Care. 

Not Able To Inflate or 
Deflate the Cushion

Confirm that the inflation valve is open. Inspect the inflation valve and hose for 
damage. 

Uncomfortable or Unstable

Confirm that:

 - the inflation valve is in the front, on the left side of the seated individual.

 

- the cushion is not underinflated or overinflated.

 

- the cushion cells and the top of the cover are facing up. 

 

- the cushion is centered beneath the individual.

 

- the cushion is properly sized to the individual and the wheelchair.

Allow the individual at least one hour to adjust to the cushion.

The Cushion Slides on the 
Wheelchair

Make sure the non-skid bottom of the cushion cover is facing away from the 
individual. Use directional labels on the cushion and on the cover to orient 
the cushion. Use hook and loop fasteners to further secure the cushion to the 
wheelchair.

The Cushion is Stiff

If the cushion has been in temperatures lower than 32° F (0° C) and exhibits 
unusual stiffness, allow the cushion to warm to room temperature.

Component is Damaged

 Contact Customer Care for replacement.

Storage: Clean and disinfect the product before storing. Open the inflation valve. Store the product in a 
container that protects the product from moisture, contaminants and damage.

Disposal: The components of the products in this manual are associated with no known environmental hazards 
when properly used and when disposed of in accordance with all local/regional regulations. Incineration must 
be performed by a qualified, licensed waste management facility.

Recycling: Contact a local recycling agency to determine recycling options for the product. For more recycling 
information, contact ROHO, Inc.

Storage, Disposal and Recycling

Summary of Contents for ROHO MOSAIC

Page 1: ...be given to the user of this product Operator Individual or Caregiver Before using this product read the instructions and save for future reference s h a p e f i t t i n g t e c h n o l o g y ROHO MOSAIC Cushion Operation Manual ...

Page 2: ...oting Storage Disposal and Recycling 6 Cleaning and Disinfecting 7 Product Specifications Limited Warranty 8 Español 9 Français 17 Deutsch 25 Italiano 33 Nederlands 41 Dansk 49 Svenska 57 Norsk 65 Suomi 73 Português 81 ROHO products may be covered by one or more U S and foreign patents and trademarks including ROHO shape fitting technology and MOSAIC 2017 ROHO Inc Rev 12 15 2017 ...

Page 3: ...r It will NOT support you in water If you are unable to perform any tasks described in this manual seek assistance by contacting your clinician equipment provider distributor or ROHO Inc DO NOT expose the cushion to any source of high heat including heating pads Exposure to high heat will accelerate aging and damage the product the benefits provided by the cushion may be reduced or eliminated incr...

Page 4: ...e carrying handle on the cover Using a pump cover or repair kit other than those provided by ROHO Inc may void the product warranty DO NOT modify the cushion or any components Doing so may result in damage to the product and will void the warranty Periodically check components for damage and replace if necessary See TROUBLESHOOTING To order replacement parts contact your equipment provider or ROHO...

Page 5: ...over the inflation valve Open the inflation valve b Inflate the cushion until all of the air cells feel firm c Close the inflation valve and remove the hand pump 2 Carefully follow the instructions for COVER PLACEMENT Cover Placement Note Keeping a cover on your cushion will help to protect the cushion components A cover will also help to keep the air cells together which may aid in slide board tr...

Page 6: ...inflation valve Warnings Make sure that there is at least in 1 5 cm of air supporting the individual s lowest bony prominences After setting up the cushion the first time check inflation frequently at least once a day Follow the Hand Check instructions above Close Open A sink down into the cushion and B float above the cushion base A B Proper Cushion Inflation Setting 1 1 5 cm 2 5 cm recommended d...

Page 7: ...dual and the wheelchair Allow the individual at least one hour to adjust to the cushion The Cushion Slides on the Wheelchair Make sure the non skid bottom of the cushion cover is facing away from the individual Use directional labels on the cushion and on the cover to orient the cushion Use hook and loop fasteners to further secure the cushion to the wheelchair The Cushion is Stiff If the cushion ...

Page 8: ...ning products that contain petroleum or organic solvents including acetone toluene Methyl Ethyl Ketone MEK naphtha dry cleaning fluid adhesive remover oil based lotions lanolin or phenolic based disinfectants ozone gas ultraviolet light cleaning methods To Clean the Cushion Remove the cover close valve s and place in a large sink Hand wash using mild liquid hand soap hand dishwashing liquid laundr...

Page 9: ...ure the cushion in the chair Refer to cover care label for material content Sizing all measurements are approximate W D W x D in W x D cm MOSAIC 1616 16 x 16 41 5 x 41 5 MOSAIC 1618 16 x 18 41 5 x 46 5 MOSAIC 1717 17 x 17 44 0 x 44 0 MOSAIC 1816 18 x 16 46 5 x 41 5 MOSAIC 1818 18 x 18 46 5 x 46 5 MOSAIC 2018 20 x 18 51 5 x 46 5 Cell Height Range 2 3 in 6 5 7 5 cm Width W and Depth D measured edge ...

Reviews: