Perlick US10KP Installation And Operation Instructions Manual Download Page 8

8

Form No. Z2026

Rev 01.28.09

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Replacement Parts

How to Order Replacement Parts 

 

Contact your local Perlick dealer to order  
replacement parts. 

be prepared to provide the model and serial num-
ber of the cooler. The serial number is
printed on a label which is attached to the inside 
wall, adjacent to the evaporator housing.

SELF-CONTAINED UTILITy COOLERS
FOUR KEG

TEN KEG

Description

Part Number

Description

Part Number

Compressor Only

57499

Compressor Only

57860

Condensing Unit Fan Motor

57513

Condensing Unit Fan Motor

C15250A2

Condensing Unit Fan blade

C3150-3

Condensing Unit Fan blade

C15250A3

Evaporator Coil Assembly

57861

Evaporator Coil Assembly

57872

E xpansion Valve

57877

E xpansion Valve

57877

Temp. Control (two-wired)

57891

Temp. Control (two-wired)

57891

ALL MODEL UTILITy COOLERS

Description

Part Number

Description

Part Number

Switch

57878

Evaporator Fan Guard

57875

Light bulb

C31358

Plug button

57882

bulb Guard

C25969-1

Door Sill

57883

Thermometer

57879

Door Closure

57884

Hinged Door Assy.

57880

Light Indicator

57858

Gasket-Door Assy.

57881

Hinge

57885

Evaporator Fan Motor

57873

Handle

57886

Evaporator Fan blade

57874

Door Wiper Gasket

57908

Summary of Contents for US10KP

Page 1: ...558 5592 E Mail Perlick Perlick com www Perlick com IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint you with its operation and maintenance We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction If service is required your dealer can provide you with a list of qualified...

Page 2: ...ains through access hole in wall 20 x 1 2 I D drain line provided refrigeration R134a refrigerant insulation 4 UL Class 1 urethane foam Flame Spreading Rate 25 or less Smoke Develop Rating 450 or less DOORS Flush mounted with cam lift chrome hinges automatic door closer magnetic gaskets chrome pull handle Standard right hinged Door size 30 W x 55 H features Light ON indicator in door Light switch ...

Page 3: ...rance is required between the top of the utility cooler and the ceiling of the building in which it is being installed Self contained Units Sufficient clearance above the cooler must be allowed for ceiling panel and condensing unit installation For ventilation requirements see page 7 The Cam Lock Fastening Method This utility cooler utilizes the cam lock fastening method See illustration on below ...

Page 4: ...mbly 1 Place do not slide all sections into position 2 Each panel is numbered on the edge For a four keg cooler follow the assembly order on page 5 For a ten keg cooler the assembly order appears on page 6 Note If ceiling height in building is restricted panel s can be carried through the door open ing and placed into position from inside the cooler 3 Install cap plugs in all cam lock holes 4 Seal...

Page 5: ... the right to change specifications without prior notice Four Keg Cooler Assembly Assemble panels as follows Section 1 Floor Section 2 Left Wall Section 3 Left Back Wall Section 4 Right Back Wall Section 6 Front with Door Section 5 Right Wall Section 7 Ceiling FRONT VIEW FLOOR 3 PANEL NO S UNIT COOLER 4 6 1 5 7 2 ...

Page 6: ...ooler Assembly Assemble panels as follows Section 1 2 Floor Section Section 3 Left Wall Section 4 Left Back Wall Section 5 Right Back Wall Section 3A Right Wall Section 6 Right Front Wall Section 7 Door Section Section 8 Left Front Panel Section 9 Celing Panel with Evaporator Housiing Section 10 Celing Panel FRONT VIEW COOLER UNIT COOLER PANEL NO S 4 5 3 3A 9 2 1 6 8 10 10 7 9 ...

Page 7: ...Ventilation Requirements Air cooled units must be furnished with sufficent ventilation to maintain their efficiency The table at right indicates the minimum room size cubic footage only the space above the condensing unit can be used When the room size is below minimum some type of forced ventilation must be provided There should be nothing on or around the machin ery compartment area which will r...

Page 8: ...Compressor Only 57499 Compressor Only 57860 Condensing Unit Fan Motor 57513 Condensing Unit Fan Motor C15250A2 Condensing Unit Fan Blade C3150 3 Condensing Unit Fan Blade C15250A3 Evaporator Coil Assembly 57861 Evaporator Coil Assembly 57872 E xpansion Valve 57877 E xpansion Valve 57877 Temp Control two wired 57891 Temp Control two wired 57891 all model UTILITY COOLERS Description Part Number Desc...

Page 9: ...ions without prior notice Wiring Diagram Four Keg Self Contained Cooler OVERLOAD RELAY FAN GREEN BROWN WHITE WHITE WHITE WHITE WHITE BROWN BROWN LIGHT SWITCH BLACK BLACK BLACK EVAPORATOR FAN MOTORS ELECTRONIC THERMOSTAT 4 MIN ON DELAY ALTERNATE THERMOSTAT STANDARD BLACK GREEN GREEN COMPRESSOR TERMINALS CAPACITOR L1 1 2 C R S L2 ...

Page 10: ...rior notice Wiring Diagram Ten Keg Self Contained Cooler OVERLOAD RELAY 1 L 3 1 C R S 5 M 2 GREEN BROWN GREEN WHITE EVAPORATOR FAN MOTORS BLACK WHITE WHITE BLACK LIGHT SWITCH BLACK WHITE FAN CONDENSER COMPRESSOR TERMINALS BROWN GREEN WHITE RED YELLOW BLUE CAPACITOR ELECTRONIC THERMOSTAT 4 MIN ON DELAY ALTERNATE THERMOSTAT STANDARD BLACK BROWN ...

Page 11: ...11 Form No Z2026 Rev 01 28 09 Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice ...

Page 12: ...8300 West Good Hope Road Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail Perlick Perlick com www Perlick com Form No Z2026 Rev 01 28 09 ...

Reviews: