18” SHALLOW-DEPTH SERIES
Operation/Installation Manual
18” SHALLOW-DEPTH SERIES
Operation/Installation Manual
INSTALLATION
CAUTION
Finished flooring should be protected with
appropriate material to avoid damage from
moving the unit.
If unit is built into cabinetry, allow clearance for
unit to be removed from opening for potential
service requirements.
If unit has been laid on its back or sides, place
unit upright and allow minimum of 24 hours
before connecting power.
1.
Plug the unit into the 15 amp grounded outlet
located in the installation opening. With power
applied to the unit, check that lighting and
cooling function operate properly, then turn off
power to the wall outlet at the circuit breaker.
WARNING
Shut off power to the wall outlet before
installing unit into the opening.
2.
Check that the following are level and square:
- front face and interior opening
- installation opening and floor surface
- countertop bottom front edge
IMPORTANT:
The floor under the unit must be at
the same level as the surrounding finished floor.
3.
If all surfaces are level, refer to Figure 3 and
perform the following:
A.
Measure from the floor to the bottom of the
front edge of the countertop.
B.
Measure the rear of unit cabinet from floor to
top of cabinet, at back corners.
C.
Adjust rear legs so B measurement equals A
measurement. Using an adjustable wrench
or pliers, turn legs counterclockwise to raise
the unit or clockwise to lower the unit.
IMPORTANT:
Leveling legs should not extend
more than 3/4” from bottom of unit.
4.
Slide unit into position. Make sure the rear
levelling legs slide under the anti-tip brackets.
Push the unit into the opening until the door
is flush with the surrounding cabinetry, or
until the rear legs are tight against the anti-tip
brackets.
IMPORTANT:
The rear levelling legs must be
engaged under the anti-tip brackets.
5.
Shim the front of the unit so the front door is
flush with the surrounding cabinetry. Adjust
the front legs to support the countertop at
the shimmed height. Using an adjustable
wrench or pliers, turn legs counterclockwise
to raise the unit or clockwise to lower the unit.
Countertop should be resting on top of the unit.
IMPORTANT:
The rear levelling legs must be
engaged under the anti-tip brackets.
CAUTION
The prevent damage to the countertop and
unit underneath, do not place heavy objects
on countertop directly above the unit.
6.
Check interior door openings inside unit to
ensure unit is level.