SEASONAL MAINTENANCE FOR UL-APPROVED OUTDOOR 
MODELS

Winterizing

This process should occur when the daily low temperatures is at 
or below the temperatures stated below:
Freezer models: 32° F
Refrigerator models: 38° F
Beverage Center: 42° F
Wine Reserve: 45° F

It is best to winterize your unit before the low temperatures 
listed above.

1. Turn the unit to OFF position by pressing the OFF button on 

the controller. The controller displays the word “OFF”  and, 
for Signature Series models, turn the master switch located 
behind the grille off (if the power cord is accessible, unplug 
the power cord. If not, turn off the circuit breaker to the 
electrical receptacle the cabinet is plugged into).

2. Remove all contents from the unit.
3. Remove the front grille.
4. Clean the condenser by using a vacuum cleaner to remove 

loose debris (leaves, dirt, etc.) that may have accumulated 
inside the grille.

5. Reinstall the front grille.
6. Clean the interior of the unit using stainless steel cleaner and 

polish (see page 9).

7. Clean the exterior of the unit using stainless steel cleaner and 

polish (see page 9). 

NOTE: Do not place a cover over the unit. While not required, you may 
choose to remove the unit from the outdoor location and store indoors.

CAUTION

Operating the unit at temperatures 
lower than those recommended will 

void the warranty.

Spring Start-Up

This process should occur after the daily low temperatures is 
above the temperatures stated below:
Freezer models: 32° F
Refrigerator models: 38° F
Beverage Center: 42° F
Wine Reserve: 45° F

1. Remove the grille.
2. Check the condensing unit to ensure it is clear of loose debris, 

and clean as necessary with a vacuum cleaner.

3. Reattach front grille to the unit.
4. Clean the interior of the unit using stainless steel cleaner and 

polish (see page 9).

5. Clean the exterior of the unit using stainless steel cleaner and 

polish (see page 9).

6. Plug the unit into the electrical receptacle or turn on the 

circuit breaker.

7. Turn on the master switch located behind the grille if model 

is Signature Series. Press the OFF button one time to turn 
the unit on. The controller display will show the actual 
temperature inside the cabinet.

8. The cooling process will begin to bring the unit to the set 

temperature. It’s recommended you run the unit for 24 hours 
to stabilize the operating temperature before using.

DANGER

Never attempt to repair or perform 
maintenance on the unit until the 

main electrical power to the unit has been disconnected!

 

LED REPLACEMENT

Call your Perlick Factory Authorized Service Center. For the 
location of the Service Center in your area, contact your selling 
dealer, inquire via the web at www.perlick.com, E-mail us at 
[email protected], or call (800) 558-5592 during normal 
business hours.

Summary of Contents for HA24BB

Page 1: ...PERLICK RESIDENTIAL UNDERCOUNTER REFRIGERATION To prevent appliance damage and injury read these instructions thoroughly prior to operation UNDERCOUNTER USE CARE GUIDE FORM NO Z2669 REV A 12 15 2020...

Page 2: ...Residential undercounter product This manual has been prepared to assist you in the installation of your cabinet and to acquaint you with its operation and maintenance This manual has been prepared to...

Page 3: ...ll void the warranty NOTICE This product contains blown foam insulation using blowing agent R 611 Methyl Formate The foam in this product does not contain HFC s CFC s or HCFC s All models covered in t...

Page 4: ...ly 2 Place the bottle in the desired area for 24 hours Refrain from opening the unit during the testing period After 24 hours check the temperature of the water Adjust the temperature accordingly usin...

Page 5: ...emperature Press the DOWN arrow button to see the minimum stored tem perature To reset the minimum stored temperature while dis played press and hold the SET button until rst flashes in the display On...

Page 6: ...ors CAUTION Operating the unit at temperatures lower than those recommended will void the warranty Spring Start Up This process should occur after the daily low temperatures is above the temperatures...

Page 7: ...While many traditional cleaners are loaded with chlorides the industry is providing an ever increasing choice of non chloride cleaners If you are not sure of chloride content in the cleaner being use...

Page 8: ...soak with a clean cloth Let stand for 15 minutes or more according to directions on package then rinse and wipe dry Rust dicoloration or corrosion caused by cleaning agents containing hydrochloric mur...

Page 9: ...led Contact Perlick Technical Service at 800 558 5592 LED Controller display is flashing HA Internal compartment has exceeded the high temperature alarm preset value for over 30 minutes Make sure the...

Page 10: ...product was recently placed in the cabinet Wait 24 hours for product to chill then recheck the temperature System runs for a long period of time Condenser is dirty or obstructed Clean the condenser a...

Page 11: ...perlick customer service 800 558 5592 11 PERLICK RESIDENTIAL UNDERCOUNTER USE CARE GUIDE NOTES...

Page 12: ...8300 West Good Hope Road Milwaukee WI 53223 USA perlick com residential 800 558 5592 Perlick Residential is a division of Perlick Corporation 2020 Perlick Corporation FORM NO Z2669 REV A 12 15 2020...

Reviews: