PLug-in-CorD
WHite
WHite
eVaP
Fan
ConD
Fan
DeFrost
temP. Limit
sWitCH
oPen
@ 40
ϒ
F
CLose
@ 25
ϒ
F
normaL CLoseD
Hot gas DeFrost
soLenoiD
DeFrost CYCLe:
1) aFter 220 minutes:
• a2 oPens.
• b1 CLoses.
• Hot gas VaLVe oPens.
• on DeLaY reLaY ContaCt
CLoses 1 to 2, in 3 minutes.
• tHermostat is bYPasseD.
• ComPressor restarts aFter
3 minutes For Hot gas DeFrost.
2) Limit sWitCH oPens at 40
ϒ
F:
• ComPressor PoWer oFF.
• Hot gas remains energiZeD.
3) aFter 20 minutes:
• b1 oPens.
• Hot gas VaLVe is De-energiZeD.
• a2 CLoses.
• ComPressor starts tHrougH
temPerature ControL.
a2 reD
reD
temPerature
ControL
WHite
WHite
internaL
ConneCtions
bLa
CK
bLa
CK
b (Po
Wer)
s.P.s.t. momentarY
ContaCt DeFrost sWitCH
W/ inDiCator LigHt
on DeLaY
reLaY
t15
t14
b1
b2
a
a2
a1
t11 t12 t13
1
s.s. timer
reLa
Y
reLa
Y
3
3
3
2
2
2
1
6
5
4
4
W
b
to ConDensing
unit
Avoiding Stainless Steel Corrosion
Corrosion can be prevented by following product
cautions, cleaning instructions and avoiding use
of certain chemicals or objects which will cause
stainless steel corrosion.
STAINLESS STEEL ENEMY
■
Steel wool or steel scouring pads
■
Cherry/Orange/Olive juice
■
Chlorine Bleach
■
Sharp Objects
5
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2255
Rev. 01.04.09
Wiring Diagram –
single Door Freezer
Cleaning Instructions –