background image

LINDR FLOW-THROUGH

CONTACT COOLING

Number 009-2020 REV00        Valid 2020-03-09

INSTRUCTION MANUAL

ENGLISH

                         

                     

KONTAKT 300/K 

TWIN POWER

 

GREEN LINE

                     
                     

KONTAKT 300     

TWIN POWER

 

GREEN LINE

       

Summary of Contents for KONTAKT 300

Page 1: ...LINDR FLOW THROUGH CONTACT COOLING Number 009 2020 REV00 Valid 2020 03 09 INSTRUCTION MANUAL ENGLISH KONTAKT300 KTWINPOWERGREENLINE KONTAKT300 TWINPOWERGREENLINE ...

Page 2: ...ing the device It contains important information for its correct and safe use WARNING Not following instructions may cause injury or damage the device SYMBOLS AND MARKINGS USED IN THE MANUAL DANGER Risk of injury by electrical current NOTE This symbol indicates information and recom mendations for the user WARNING The cooling system contains flammable coolant R290 propane LINDR CZ s r o Sadová 132...

Page 3: ...nd pressurisation 13 Inlet and outlet marking 14 Built in air compressor 15 How to work with speed fittings 16 Thermostat placement 17 Temperature and adjustment 18 Keg tapping and untapping 19 Putting into operation 20 Maintenance 21 Inspection before every use 22 Periodic checks 23 Environmental protection 24 Cleaning the condenser 25 Sanitation by water 26 Changing the illuminated advertising p...

Page 4: ...vice is designed for flow cooling of beverages dispensed from kegs Any other use is considered impermissible and therefore dangerous The supplier is not liable for dam age caused by incorrect use DO NOT USE THE DEVICE FOR PURPOSES OTHER THAN THOSE STATED BY THE MANU FACTURER General safety principles Observe the follow ing safety instructions The supplier is not liable for damage caused by activit...

Page 5: ...nd repair WARNING Do not use open flame or po tential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the cool er so that heat created by the cooling unit can be vented sufficiently WARNING Do not place objects that could prevent air circulation on top of the cooler 5 INSTALLATION AND PLACEMENT Place the cooler onto a stable level surface maximum perm...

Page 6: ... by an authorised service centre Warranty provided by a retailer outside of the territory of the Czech Republic is gov erned by the agreement between the retail er and the buyer in their mutual relationship this agreement is not directly linked to the manufacturer The agreement does not give the buyer the right to submit warranty claims to the manufacturer Transport expenses or other costs are not...

Page 7: ...contact cooled dispensing system 7 ...

Page 8: ... 11 1 Outlet for Keg Pressurisation Variant of connection with the use of a bushing the hose is fitted onto the bushing and affixed with a clip figure 8 A figure 8 b figure 8 C NOTE The tap is not included SPO 02216 Seal 5 8 VYR 02359 Spacer ring ...

Page 9: ... 8 x 1 2 12 7 mm rapid coupling onto the keg coupler figure 9 A figure 9 b figure 9 c figure 9 d WARNING Before you screw the rapid coupling onto the 5 8 thread make sure the keg coupler air inlet for delivery medium has a lip valve check valve fitted on it 5 8 5 16 8mm 5 8 1 2 12 7mm ...

Page 10: ... from the cooling device into the 5 8 1 2 12 7 mm rapid coupling beverage outlet on the keg coupler Plug the 5 16 air hose leading from the cool ing device into the 5 8 5 16 8 mm rapid coupling air inlet on the keg coupler To connect air supply to two kegs use a 5 16 8 mm Y adapter figure 10 A figure 10 b Drink Air 12 BEVERAGE SUPPLY CONNECTION AND PRESSURISATION SPO 01365 DM Y 8mm ATWD 0808M blac...

Page 11: ...contact cooled dispensing system 11 obrázek 11 a NOTE The figure shows a model connection example for other connection options consult a specialised company or the manufacturer Drink Drink Air Air ...

Page 12: ...12 13 INLET AND OUTLET MARKING figure 12 c figure 12 a figure 12 b Outlet 1 Outlet 2 ...

Page 13: ...with a molecule filter for the drawn in air figure 13 a 15 HOW TO WORK WITH SPEED FITTINGS 15 1 Speed fitting Installation Grasp the speed fitting and insert the hose all the way inside the speed fitting body ca 20 mm The end of the hose must be straight so that it plugs fully into the coupling If the hose will not go in moisten the end of the hose figure 13 b 15 2 Speed fitting Removal Hold the g...

Page 14: ...THERMOSTAT PLACEMENT The mechanical thermostat with 1 7 numeri cal scale located on the front of the cooler figure 14 A 0 OFF 1 MAX BEVERAGE TEMPERATURE 7 MIN BEVERAGE TEMPERATURE WARNING If you are using the cooler to cool non alcoholic beverages set the thermostat knob to no 5 at the most otherwise there is a risk of the beverage freezing in the cooler s tubing and damaging the device ...

Page 15: ...re 15 A figure 15 b figure 15 c figure 15 d figure 15 e 18 KEG TAPPING AND UNTAPPING 18 1 Keg Tapping Procedure for tapping a keg using an S system keg coupler S system keg coupler WARNING Make sure the adapter is clean before tapping the keg ...

Page 16: ...eg using an A system keg coupler A system keg figure 16 d figure 16 e 18 2 Keg Untapping Procedure for untapping a keg using an S system keg coupler figure 16 a figure 16 b figure 16 c WARNING Make sure the adapter is clean before tapping the keg ...

Page 17: ... Check that all the joints and connections are sufficiently tight WARNING If leakage is found untap the keg according to point 18 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are unsure how to proceed contact a service centre 7 Use the dispensing tap to let out some of the beverage and check that there is no water in the device WARNING Never...

Page 18: ...he cooler 23 ENVIRONMENTAL PROTECTION Waste Sorting 22 PERIODIC CHECKS 1x a week check that the lead in cable is undamaged and that the plug is firmly in the socket 1x a week check that the device is not ex posed to radiant heat 1x a week check that air circulation is not obstructed 1x a month check the cooling unit s con denser and clean it regularly 1x a year have an engineering inspector check ...

Page 19: ...Sanitation adapter is not included Can be purchased as an accessory for the cooler figure 19 d figure 19 c WARNING Maximum water temperature must not exceed 25 C Sanitation procedure Once you have finished a keg connect the keg coupler to the sanitation adapter the same way as if you were tapping a keg Once connected turn the bar tap lever to open position and keep it open until clean water flows ...

Page 20: ...vice from power 2 Remove the four M4x20 screws 3 Remove the covering plexiglass 4 Remove the current advertisement placard 5 Insert a new advertisement placard 6 Replace the covering plexiglass 7 Insert spacers and four screws lightly tighten M4x20 max 0 2 Nm WARNING Tighten the screws fastening the plexiglass gently Maximum torque is 0 20 Nm UNI 02431 Kontakt 300 advertising placard PLA 02072 Kon...

Page 21: ...contact cooled dispensing system 21 figure 21 a ...

Page 22: ...tion check the cleanliness of condenser plates device overheats place the device in a colder environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg air compressor does not switch on press the switch on the cooler by the device K profi turn the regulator screw to the right air compressor does not switch off leakage pull out and reinsert the...

Page 23: ...5 Frame dimensions WxDxH mm 595 x 390 x 550 595 x 390 x 550 Net weight kg 76 70 29 TECHNICAL DATA Do not forget to specify the following type of defect product type production year product s serial number found on the label Ordering Components ALWAYS USE ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufact...

Page 24: ......