Connecting the Regulator to the
CO

2

 Cylinder 

 

  ■ 

Remove blue plug from regulator fitting. 

 

(Note: Do not remove the carbonic washer).

  ■ 

Screw regulator onto gas cylinder valve.  

 

Tighten with wrench until vertically straight.  

 

Be sure that shut-off valve (

black lever

) on  

 

regulator is in the OFF (

horizontal

) position.

  ■ 

Place a screw clamp over end of red air line  

 

and push onto regulator tailpiece. Tighten  

 

clamp with a screwdriver.

Adjusting the CO

2

 Gas flow 

  ■ 

Turn regulator adjusting screw counterclock- 

 

wise until it turns freely.

  ■ 

Turn hand valve counterclockwise on CO

2

 

 

cylinder to the fully open position.

  ■ 

Turn regulator adjusting screw clockwise until  

 

desired pressure is reached (approximately  

 

12-15 lbs.). The desired pressure may vary  

 

based on location/elevation. Tighten stop nut  

 

on adjusting screw.

  ■ 

Open shut-off valve on bottom of regulator.

 

CO

Leak Test 

Dilute a small amount of liquid dish washing soap 

and rub the soapy mixture around each connec-

tion. If bubbles appear, tighten connection.

 

Replacing CO

Gas Cylinder 

  

  ■ 

Turn CO

2

 hand valve clockwise until seated and  

 

close shut-off valve on regulator.

  ■ 

unscrew regulator from cylinder fitting.

  ■ 

Replace carbonic washer (Part No. 157F2P), 

 

if needed and reattach regulator to filled  

 

cylinder.

  ■ 

Turn CO

2

 hand valve counterclockwise until 

 

fully open. Turn regulator shut-off valve to 

 

open position.

  ■ 

Adjust CO

2

 gas flow as required, turning

 

clock wise for higher pressure.

Proper CO

Handling 

  

always

...

  ■ 

Connect a regulator (reducing valve) to  

 

CO

2

 cylinder.

  ■ 

Secure cylinder in upright position whether in  

 

storage or in use.

  ■ 

Keep cylinder away from heat. Rupture disc  

 

vents at 122° F. maximum.

  ■ 

Ventilate room after high pressure gas leakage.

  ■ 

Check the last DOT test date on cylinder neck  

 

before filling. If more than five years old, the  

 

cylinder must be retested to DOT specifications.

  ■ 

Be sure CO

2

 cylinder outlet fitting is free of dust  

 

or dirt before attaching regulator.

  ■ 

Store CO

2

 cylinder and regulator assembly  

 

upright.

  ■ 

Allow only properly trained and experienced  

 

personnel to handle high pressure gas. 

 

never

...

  ■ 

Connect cylinder directly to a keg without a 

 

regulator (reducing valve).

  ■ 

Drop or throw regulator or CO

2

 cylinder.

  ■ 

Transport CO

2

 cylinder in a closed vehicle.

  ■ 

Apply oil to a regulator. 

 

  ■ 

Shut off CO

2

 cylinder when not in use. You will  

 

not save gas by doing so!

  ■ 

Allow untrained, inexperienced personnel to  

 

handle high pressure gas.

failure to heed this warning could result in  

personal injury or death.

Form No. Z2323

Rev. 06.26.10

5

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Installation and Tapping

ArctiCold Draft Dispenser

CO2

PRESSURE

GAUGE

CO2 

GAS 

DRUM

REGULATOR

FITTING

REGULATOR

ADJUSTING

SCREW

FITTING FOR

RED AIR HOSE

SHUT-OFF VALVE

(BLACK LEVER IN

CLOSED POSITION)

HAND

VALVE

PERLICK

PSI

10

50

0

60

20

40

30

Summary of Contents for DC90ACLT

Page 1: ... perlick com Click on Commercial then Service You will see the link to Warranty Registration Form You must complete and submit this form or the installation date will revert back to the ship Date The unit comes with a one year parts warranty This manual has been prepared to assist you in the installation of your ArctiCold Draft Dispenser and to acquaint you with its operation and maintenance We de...

Page 2: ... Epoxy coated aluminum fin and copper tube evaporator coil Digital temperature control Self defrosting glycol mixture 1 3 propylene glycol to 2 3 distilled water Ventilation All sides of unit must be unobstructed to ensure adequate ventilation Plumbing Evaporator condensate and beer waste is pre plumbed to a waste tank located in the CO2 compartment electrical Unit is furnished with 3 prong NEMA 5...

Page 3: ...e compressor and void the warranty Remove the bottom front grille to access the machine compartment Connect the power cord to a separate dedicated circuit as described in the electrical section of this manual Turn on the rocker switch labeled circulating pump and check for glycol leaks Next turn on the rocker switch labeled condensing unit The flash chill heat exchangers and evaporator coil circui...

Page 4: ...de of the cabinet Important Be sure to close this valve when untapping keg CAUTION Do not use keg coupler as a handle to lift keg Priming the Beer System Plug in top refrigeration deck 15 amp plug and allow condensing unit to cycle at least once circulation pump will run continuously before tapping the keg Couple beer keg to system Beer temperature in keg should not exceed 42 F Apply 14 17 PSIG ca...

Page 5: ...e to open position Adjust CO2 gas flow as required turning clock wise for higher pressure Proper CO2 Handling always Connect a regulator reducing valve to CO2 cylinder Secure cylinder in upright position whether in storage or in use Keep cylinder away from heat Rupture disc vents at 122 F maximum Ventilate room after high pressure gas leakage Check the last DOT test date on cylinder neck before fi...

Page 6: ...d maintain the quality of the draft beer Greenish or yellowish colored material on the faucet may indicate bacterial growth Yeast All domestic draft beers contain a small amount of yeast which remains in the beer from the fermentation process When the temperature of draft beer exceeds 50 a process of secondary fermentation may take place The beer faucet may exhibit a white colored substance yeast ...

Page 7: ... a clean glass Place the glass at a 45 angle one inch below faucet Do not let the glass touch the faucet Open the faucet all the way Step 1 Let the remaining beer run straight down the middle of the glass This ensures proper release of CO2 by producing a 3 4 to 1 foam head Step 3 After the glass has reached half full gradually bring the glass to the upright position Step 2 Close the faucet quickly...

Page 8: ...Form No Z2323 Rev 06 26 10 8 Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Wiring Diagrams ArctiCold Draft Dispenser ...

Page 9: ...s improvement Therefore we reserve the right to change specifications without prior notice Glycol Loop Diagrams ArctiCold Draft Dispenser FLASH CHILL FIN COIL CIRCUIT GLYCOL TANK TUBE IN TUBE TUBE IN TUBE EVAPORATOR FIN COIL PUMP REFRIG DECK CABINET HEAT EXCHANGER ...

Page 10: ...ycol system should be checked before each operation to ensure an adequate level The glycol reservoir can be accessed by removing the lou vered cover on the refrigeration deck The reservoir is located at the right rear of the deck see figure A Remove the sponge insulation and unscrew the cover While using a mirror ensure the glycol level is at the visible seam inside the reservoir located approxima...

Page 11: ...Form No Z2323 Rev 06 26 10 11 Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice ...

Page 12: ...ad Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail Perlick Perlick com www Perlick com Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 12 ...

Reviews: