Perlick 48

© 2009

8

24” Signature Series Operation / Installation Manual

26 35/64"

Ø

D

D

B

B

Ø

19

/

64

15

/

32

”deep 

7

/

16

13

/

64

30 

15

/

64

” 

11

/

32

Hole drilled at both ends 

29 

3

/

8

” 

11

/

16

Section D-D

Scale 1:2

Rear

7

/

8

3

/

4

Front

29

/

64

3

/

4

” Hole detailed in view C

Section B-B

All features called out

in detail views B-B & C apply

only to panels being used

on locking doors

0”

27

/

32

15

/

64

11

/

16

1

/

8

1

/

2

” Deep

11

/

16

15

/

64

25

/

32

27

/

32

0”

13 

9

/

32

10 

9

/

32

13

/

64

23 

9

/

16

22 

23

/

32

” 22 

3

/

16

19 

57

/

64

18”

19 

7

/

64

These (2) holes

not to be drilled

for a door with lock

25 

49

/

64

24 

43

/

64

Rear view

13 

39

/

64

16 

39

/

64

15 

7

/

64

On locking

doors only

Ø 

1

/

8

1

/

2

” Deep

17

/

32

25

/

32

R 1 

11

/

16

2”

7

/

32

3

/

64

1 1/16"

Ø 

3

/

4

Thru

27

/

64

13

/

64

1

/

8

13

/

16

11

/

64

27

/

64

19

/

32

Detail C

Scale 1:2

C

figure 8. Glass Wood Overlay Panel

figure  9. drawer Solid Wood Overlay

B

C

  

15 

1

/

32

22 

23

/

32

” 19 

57

/

64

13 

9

/

32

” 10 

9

/

32

11

/

16

27

/

32

” 0

0

27

/

32

11

/

16

1

/

64

1

/

64

11 

23

/

64

14 

3

/

16

23 

9

/

16

Rear View

3

/

4

Summary of Contents for 48" Signature Series

Page 1: ...here minor injury or product Warranty Registration To request information or service the model number and serial number must be provided This information is located on the inside ceiling of the unit and on the warranty registra tion card included with information packet shipped with the unit IMPORTANT Read through the included warranty statement then complete and mail the Warranty Registration Car...

Page 2: ...hecondensereverythreemonthscancause the unit to malfunction This could void the warranty Never install the unit behind closed doors Be sure front louvered toe plate is free of obstruction Obstructing free air flow can cause unit to malfunction and may void the warranty caution Use only Perlick replacement parts Imitation parts can dam age the unit and may void the warranty Installation Specificati...

Page 3: ...cal outlet must be located 13 1 16 distance same on both sides of cabinet 4 1 2 min clearance to side wall on corner installation 24 25 32 door swing clearance 98 min door swing for pull out shelf clearance 25 27 64 23 15 16 22 1 8 3 39 64 1 53 64 23 7 8 34 5 16 Figure 1 Dimensions ...

Page 4: ...g prong from the plug Never use a 2 prong grounding adapter Never use an extension cord to connect power to the unit If a 2 prong wall receptacle is encountered or a longer power cord is required contact a qualified electrician to install the proper 3 prong receptacle in accordance with applicable electrical codes Danger Failure to comply with the above electrical guidelines may result in possible...

Page 5: ... kit Installation Caution Finished flooring should be protected with appropriate mate rial to avoid damage from moving the unit If unit has been laid on its back or sides place unit upright and allow minimum of 24 hours before connecting power 1 Plug the unit into the 15 amp grounded outlet located in the installation opening With power applied to the unit check that lighting and cooling function ...

Page 6: ...et pull the front end up and out then forward to remove Figure 5 3 Place bracket at the desired position Push the rear hook into the rear key slot Set front of bracket on the wall hook 4 Repeat for other bracket s 5 Push extenders completely into the unit Align the shelf grooves with the extenders and slide completely into the unit Door Options Perlick residential units offer a variety of door pan...

Page 7: ... The glass wood overlay panel should not weigh more than 10 pounds The following instructions cover installing a solid wood overlay or glass wood overlay panel and handle to a door or drawer IMPORTANT Contact the factory for full size wood overlay panel layouts Refer to Figure 7 for solid wood overlay panel Refer to Figure 8 for glass wood overlay panel Refer to Figure 9 for drawer wood overlay pa...

Page 8: ...1 2 Deep 3 11 16 2 15 64 1 25 32 27 32 0 13 9 32 10 9 32 13 64 23 9 16 22 23 32 22 3 16 19 57 64 18 19 7 64 These 2 holes not to be drilled for a door with lock 25 49 64 24 43 64 Rear view 13 39 64 16 39 64 15 7 64 On locking doors only Ø 1 8 1 2 Deep 17 32 1 25 32 R 1 11 16 2 3 7 32 3 64 11 16 Ø 3 4 Thru 27 64 1 13 64 2 1 8 13 16 11 64 27 64 19 32 Detail C Scale 1 2 C Figure 8 Glass Wood Overlay ...

Page 9: ...pped with an interior light that illuminates when the door is opened A manual switch is located near the light for displaying the product through a glass door Always ensure the manual switch is in the off position before closing a solid wood or stainless steel door If manual switch is left on for an extended period of time it may increase the cabinet 1 8 x 0 312 deep 5 8 5 16 7 1 4 8 1 17 32 1 1 2...

Page 10: ... which affect the internal temperatures of the cabinet include the following Temperature setting Room temperature where installed Number of times the door drawer is opened and closed Length of time door drawer is left opened Adjacent compartment temperature Style of door installed Door gasket and sealing Amount of time internal light is illuminated Installation in direct sunlight or near a heat so...

Page 11: ...options Fast freezing cycle is started by holding button down for 3 seconds Displays and allows setpoing adjustment Used to select a parameter or confirm an operation in programming mode If held for 3 seconds while max or min temperature is displayed it will erase that temperature from memory SYMBOL STATUS ALERT DEFINITION ON FLASHING FLASHING ON ON ON ON FLASHING The compressor is running Anti sh...

Page 12: ...freezer defrost crackling is normal Control display is flashing P1 There is a thermostat failure Control display is flashing P2 There is an evaporator probe failure Control display is flashing HA The internal compartment temperature has exceeded the high temperature alarm preset value for over 30 minutes Check to ensure door is closed Check for door gasket seal Was warm product just installed Is t...

Page 13: ... Are the doors closing and sealing properly Condensation forms on the outside of the unit During periods of high humidity some condensation might appear on the outside surface The condensation will disappear when the humidity drops Meanwhile be sure doors are closing and sealing properly If condensation persists contact your Perlick Factory Authorized Service Center To obtain product information C...

Page 14: ...ith low voltage wiring not conforming electrical codes improperly maintained or modified The original Bill of Sale delivery date or serial number cannot be verified Defective parts are not returned for inspection if so required by the Perlick Corporation To receive parts and or service and the name of the nearest Perlick authorized service representative contact your Perlick dealer distributor or ...

Page 15: ... 2009 15 24 Signature Series Operation Installation Manual NOTES ...

Page 16: ... 2009 16 24 Signature Series Operation Installation Manual NOTES ...

Reviews: