Perle S-100-M2LC2 Installation Manual Download Page 4

Fast Ethernet Media Converter – Installation Guide

    

DIP Switches 

 

The DIP switches are accessible through the opening in the side of the 
enclosure  

 

Note:

 

All switch changes take effect immediately and will result in a link 

reset on both ports. 

 

DIP Switch Settings 

 

Auto Negotiation (Switch 1) 

 

Switch Position  Mode 

Up (default) 

Auto 

Down 

Off 

 
Auto: In this mode of operation the media converter will negotiate 
Ethernet parameters on the copper connection. This will ensure the 
most optimal connection parameters will be in effect. If the copper link 
partner does not support Auto negotiation, the S-100 will default to 
100 Mbps and Half Duplex mode. 
 
Off: Auto Negotiation should only be turned off, if the copper link 
partner does not support Auto Negotiation.  

When the Auto Negotiation switch is set to the OFF position, the 
media converter will operate at 100 Mbps and Full Duplex mode. 

Summary of Contents for S-100-M2LC2

Page 1: ...P N 5500301 15 Perle Fast Ethernet Media Converters Installation Guide S 100 XXXXX...

Page 2: ...on the model selected see table below Model Connector Mode Distance Wavelength S 100 M2xx2 SC ST LC MM 2 km 1 2 mi 1310 nm S 100 S2xx20 SC ST LC SM 20 km 12 4 mi 1310 nm S 100 S2xx40 SC ST LC SM 40 km...

Page 3: ...converter Auto MDIX Jumper Settings Note The factory settings for Auto MDIX will work for most installations but in the rare case that you need to modify the settings the procedure is below To access...

Page 4: ...to In this mode of operation the media converter will negotiate Ethernet parameters on the copper connection This will ensure the most optimal connection parameters will be in effect If the copper lin...

Page 5: ...ld therefore resemble a direct copper connection Standard Mode In this mode the links on the fiber and copper sides can be brought up and down independently of each other A loss of link on either the...

Page 6: ...nal Disabled The media converter will not monitor for or generate Far End Fault The following diagram is an illustration of the operation of this feature A Remote Media Converter setup for Far End Fau...

Page 7: ...at the attached device near end can negotiate its Ethernet parameters as if it was negotiating directly with the far end device The Pause switch setting on the media converter should match the capabil...

Page 8: ...ber Cable Locate a 100Base X compliant simplex 1 strand fiber cable with male connections Connect the fiber cable from one media converter to the other media converter switch fiber device Installing t...

Page 9: ...ters have three single color status LEDs located on the front panel of the unit PWR Power Test On Power is on and in normal operation Blinking slowly the unit is in loopback mode Blinking quickly the...

Page 10: ...ossover and automatically configures the connection Error Recovery In certain configurations and under specific conditions where the media converter brings down a link to convey status there is potent...

Page 11: ...ndard SW2 Down on both media converters Leave all other switches in the Up position 2 Connect the near end device to the copper connection The LKC LED indicates good copper connection If the LKC LED i...

Page 12: ...odel Mode Wavelength nm TX Power dB RX Power dB Budget dB S 100 M2SC2 MM TX 1310 RX 1310 Min 20 Max 12 Min 31 Max 14 11 S 100 M2ST2 MM TX 1310 RX 1310 Min 20 Max 12 Min 31 Max 14 11 S 100 M2LC2 MM TX...

Page 13: ...1550 Min 14 Max 8 Min 32 Max 3 18 S 100 S1SC20D SM TX 1550 RX 1310 Min 14 Max 8 Min 32 Max 3 18 S 100 S1SC40U SM TX 1310 RX 1550 Min 8 Max 3 Min 33 Max 3 25 S 100 S1SC40D SM TX 1550 RX 1310 Min 8 Max...

Page 14: ...mful interference in which case the user will be required to correct the interference at his her own expense EN 55022 Class B EN 55024 Class A Note When used with a power adapter providing low conduct...

Page 15: ...at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support...

Reviews: