18
IDS-509CPP Hardware Installation Guide
3. If the SFP module is equipped with a clasp, ensure the clasp is in the locked posi-
tion.The appropriate fiber cable can now be connected to the SFP module.
Warning:
In hazardous location installations, failure to remove the power from the source
prior to completing the connection/s to the SFP slot/s could cause an electrical arc result-
ing in a possible explosion.
Removing SFPs
SFP modules are inserted in the SFP slots on the front of the IDS switch.
1. Disconnect the fiber cable from the SFP module.
2. If the SFP module is equipped with a clasp, move it to the unlocked position and use
the clasp to pull the SFP towards you.
3. If the SFP module is not equipped with a clasp, then with your fore finger and thumb,
firmly grip the SFP and pull towards you.
Warning:
In hazardous location installations, failure to remove the power from the source
prior to removing the SFP modules from their slots could cause an electrical arc resulting
in a possible explosion.
Note:
Changing the SFP to one that operates at a different speed (ex. 1000Mbps to
100Mbps) will require a reboot of the switch.