IDS-108FPP Installation Guide

     

                                      

2

 

Overview 

This document contains instructions necessary for the 
installation and operation of the Perle IDS-108FPP 
unmanaged Ethernet switch. This Ethernet switch is a 
8-port RJ-45 switch with PoE/PoE+ capabilities on 
ports one through four. The PoE/PoE+ Ethernet ports 
function as (PSE) Power Sourcing Equipment and can 
each independently power a PD (Powered Device) 
using standard UTP cables that carry Ethernet data. 
Powered Devices must comply with the IEEE 802.3af 
or the 802at-2009 standard for PoE or PoE+ devices. 
The IDS-108FPP is available in various copper and  
fiber configurations (see table below). The fiber ports 
can be either single mode (SM) or multimode (MM) 
depending on the model selected and can operate over 
different wavelengths and distances.  Visit the Perle 
website for the most up to date installation guides, 
models and specifications. 

http://www.perle.com/

 

 

Note: xxxxxxxx(XT) indicates models numbers for this 
product line. 
TP = twisted pair 
XT = Industrial Temperature models

Model 

 

Port 1-4 

 

Port 5 - 8

 

Port 9 and 10

 

IDS-108FPP 

TP (RJ-45) 
PoE/PoE+ 
 

TP (RJ-45) 

empty 

IDS-108FPP-xxxxxxxx 

TP (RJ-45) 
PoE/PoE+ 
 

TP (RJ-45) 

1 or 2 fiber ports 
(SC or ST) 

IDS-108FPP-XT 
(Industrial Temperature 
Model) 

TP (RJ-45) 
PoE/ PoE+ 
 

TP (RJ-45) 

empty 

IDS-108FPP-xxxxxxxx-XT  
(Industrial Temperature 
Model) 

TP (RJ-45) 
PoE/PoE+ 
 

TP (RJ-45) 

1 or 2 fiber ports 
(SC or ST) 

Summary of Contents for IDS-108FPP series

Page 1: ...Perle IDS 108FPP XT Unmanaged 10 100 PoE PoE Ethernet Switches with Fiber Ports P N 5500341 10 Rev I Installation Guide...

Page 2: ...in various copper and fiber configurations see table below The fiber ports can be either single mode SM or multimode MM depending on the model selected and can operate over different wavelengths and d...

Page 3: ...puts 18 57 VDC Rugged high strength IP30 aluminum case Industrial temperature models Din rail or wall panel mounting Note In this guide the various models will be referred to as the IDS 108FPP Getting...

Page 4: ...IDS 108FPP Installation Guide 4 Front View of IDS 108FPP 8 port RJ 45...

Page 5: ...IDS 108FPP Installation Guide 5 Front View of IDS 108FPP with one or two fiber ports...

Page 6: ...e IDS 108FPP with two ST fiber ports installed Top view of the IDS 108FPP The IDS 108FPP switch has two power inputs that can be connected simultaneously If one power source fails the other source act...

Page 7: ...9 10 Port 9 10 Fiber Green LED On Link up Flashing Link up and Ethernet activity detected Off Link down Ethernet Port Status Port Link Speed Green and Yellow LEDs Port Link Green LED On Link up Flash...

Page 8: ...IDS 108FPP Installation Guide 8 Views for the IDS 108FPP...

Page 9: ...IDS 108FPP Installation Guide 9...

Page 10: ...he DIN rail fits into the slot on the top of the DIN rail clip just below the DIN rail hook and behind the spring 3 While pushing down on the unit to compress the spring rotate the bottom of the IDS 1...

Page 11: ...ve the screws into the wall leaving about 2 mm of the screw protruding from the wall to allow room for sliding the wall mount panel between the wall and the screws 5 Fix the screws to the wall and the...

Page 12: ...g of the equipment is performed by trained and qualified personnel and that the installation complies with all local and national electrical codes This unit should be installed in a restricted access...

Page 13: ...only WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous WARNING EXPLOSION HAZARD Substitution of any components on this switch...

Page 14: ...ews 0 51Nm torque 6 Ensure the wires are securely fastened 7 Re insert the Terminal block connector if removed 8 Turn on power source 9 Check that the P1 LED is On 10 If desired connect P2 power sourc...

Page 15: ...cable Connect the copper cables from each TP port RJ 45 on the IDS 108FPP switch to Ethernet enabled devices See below for 8 pin RJ 45 pinouts Remaining pins not used Fiber Port Cabling Requirements...

Page 16: ...the IDS and the other cable end to a fiber compliant device If you are making your own fiber cables remember that the RX on one side needs to go to TX on the other side and vice versa See diagram belo...

Page 17: ...See fiber specifications PoE PoE ports Up to 30 Watts per port switch RJ 45 driving up to four class 4 IEEE 802 3at type 2 PDs Alternative B ALT B MDI X pinouts Power over Pins 4 5 Positive and 7 8 N...

Page 18: ...FCC Part 15 Class A CISPR22 2008 EN55022 2010 Class A CISPR 24 2010 EN55024 2010 Note The safety certifications apply only to ambient temperatures under 60 C 140 F However the IDS 108FPP can function...

Page 19: ...RX 1310 Min 8 Max 3 Min 22 Max 3 14 IDS 108FPP S2xx40 XT SC ST SM duplex 40 km 24 9 miles TX 1310 RX 1310 Min 3 Max 5 Min 23 Max 3 20 IDS 108FPP S1SC40U SC SM simplex 40 km 24 9 miles TX 1310 RX 1490...

Page 20: ...9 miles TX 1550 RX 1310 Min 5 Max 0 Min 34 Max 3 20 IDS 108FPP DS2xx80 2 x SC SC ST SM duplex 80 km 49 7 miles TX 1550 RX 1550 Min 5 Max 0 Min 34 Max 3 29 IDS 108FPP DS2xx120 2 x SC SC ST SM duplex 1...

Reviews: