Perle 10G Media Converter module Installation Guide
9
Local Cx-10G Configuration
Test Mode (Switch 1 – Down)
Test Function (Switch 2 –Up)
Remote-Cx-10G Configuration
All switches in the Up position
Note
:
If the remote Media Converter module is not a supported Perle
media converter/ module then the remote Media Converter /module will
need to be put into loopback mode. See the documentation that came
with that Media Converter module.
Sequence of Events
1. The Local Cx-10G Media Converter module sends the remote
media converter/ module a signal to go into loopback mode.
2. The remote media converter/module turns on loopback mode.
3. Built In Test Data is sent from the Local Cx-10G media
converter module to the Remote media converter/ module
4. The Remote media converter module loops the received data
back to the Local Cx-10G Media Converter module.
5. Any test errors detected are displayed with the LEDs on the
front of the Local Cx-10G Media Converter module
6. The Built in Link Tests continue to run until Switch 1 on the
Local Cx-10G Media Converter module is set to Data mode
Port Selection (Switch 3 – Test Mode)
Switch Position
Port
Up (default)
1
Down
2
When in Test Operating mode (Switch 1- down), this switch
determines the port number.
Fiber Fault Alert (Switch 3 – Data Mode)
Switch Position
Mode
Up (default)
Enabled