SCR System Inducements
Table 5
SCR System Inducements
Warning Indicator
Stop Indicator
Emission Malfunc-
tion Indicator
Engine Power
Time
Comment
Action
OFF
OFF
OFF
Full Power
-
Normal Operation
None
ON Solid or Slow
Flashing
OFF
ON Solid
Start of Engine
Power Derate
Timer Starts, 240
Minutes Before Full
Derate
A Level 1 Induce-
ment is Active
Contact your Per-
kins dealer or
your Perkins
distributor.
If a Code has been
Activated Provide
this Information to
Your Dealer.
ON Flashing
Slowly
OFF
ON Flashing
Slowly
Derate to Engine
Power and Speed
A Level 2 Induce-
ment is Active
ON Flashing Fast
ON Solid
ON Flashing Fast
Full Engine Derate
Low Idle (RPM)
Only
A Level 3 Induce-
ment is Active
(1)
Lamp mode will depend on the issue that has been identified.
SEBU9068-03
37