N40475
Chapter 8
Page 35
Cables required
Where Used:
Connects the PCP and MMPD displays
into the J1939 data link.
The J1939 data link (item 1 figure 14) can not exceed
40 meters (131 ft.).
Requires:
MMPD drop cable
Tee to Tee cable
6-pin Tee
Termination resistor
Termination resistor (figure 15)
Used to terminate the ends of a data link run. Two
termination resistors required
Tee connector (figure 16)
Used to connect tee to tee cables.
CAN Data Link
SAE J1939-15: Unshielded twisted pair.
The CAN network operates at 250 Kb/sec, it follows
J1939-15 protocol.
J1939-15
Maximum Drops (nodes)
10
Maximum Cable Stub Length
3M
Maximum Cable Stub Length for
service connector
2.66M
Maximum Bus Length
40M
Shielded Cable
NO
Figure 14
Figure 15
Figure 16
Summary of Contents for M190C
Page 1: ...Installation Manual Part No N40475 GB Marine Power M300C M250C M216C M190C ...
Page 2: ......
Page 6: ......
Page 10: ...Contents N40475 ...
Page 18: ...Chapter 3 N40475 Page 8 ...
Page 24: ...Chapter 4 N40475 Page 14 ...
Page 26: ...Chapter 5 N40475 Page 16 ...
Page 55: ...N40475 Chapter 8 Page 45 Engine wiring harness overview ...
Page 56: ...Chapter 8 N40475 Page 46 Panel harness overview ...
Page 57: ...N40475 Chapter 8 Page 47 Wiring diagrams Engine wiring harness 1 ...
Page 58: ...Chapter 8 N40475 Page 48 Engine wiring harness 2 ...
Page 59: ...N40475 Chapter 8 Page 49 Engine panels 1 ...
Page 60: ...Chapter 8 N40475 Page 50 Interconnecting leads 1 ...
Page 61: ...N40475 Chapter 8 Page 51 Master slave option port ...
Page 62: ...Chapter 8 N40475 Page 52 Marine junction box ...
Page 63: ...N40475 Chapter 8 Page 53 Master slave option starboard ...
Page 64: ...Chapter 8 N40475 Page 54 Interconnecting leads 2 ...
Page 65: ...N40475 Chapter 8 Page 55 Engine panels 2 ...
Page 66: ...Chapter 8 N40475 Page 56 ...
Page 68: ...Chapter 9 N40475 Page 58 ...
Page 72: ...Chapter 11 N40475 Page 62 ...
Page 76: ...Chapter 12 N40475 Page 66 ...
Page 80: ...Chapter 12 N40475 Page 70 ...