Remove the plug shown in illustration 24 in order
to connect to the engine oil system. The
connection required is 9/16" x 18 tpi. Ensure that
the correct oil specification is used, refer to this
Operation and Maintenance Manual, “Fluid
Recommendations” for more information. After the
engine internal surfaces have been lubricated,
remove connector and install plug (1). Tighten plug
to a torque of 30 N·m (265 lb in). Perkins
recommends that the procedure must be
performed in a minimum ambient temperature of
10° C (50° F).
9.
Check the condition of all rubber hoses. Replace
any worn hoses. Replace any damaged hoses.
10.
Before start-up, test the cooling system for a 3
percent to a 6 percent concentration of coolant
conditioner. Add liquid coolant conditioner or a
coolant conditioner element, if equipped.
Test the coolant mixture for proper nitrite level. If
necessary, adjust the coolant mixture.
Prime the engine with clean diesel fuel before
starting.
11.
Ensure that the cooling system is clean. Ensure
that the system is full. Ensure that the system has
the correct amount of supplemental cooling
system conditioner.
12.
On the first day of operation, check the entire
engine several times for leaks and correct
operation.
SEBU9074-01